background image


The
gas
water
heater
installed
in
a
suitably
ventiled
room
,

 

in
accordance
with
the
regulations


in
force..
It
is
not
allowed
to
install
in
the
bedroom,
underground,
bathroom
or
any
other
places

with
poor
ventilation.
(For
B

23


type)



The
flue
of
the
heater
cannot
be
connected
to
a
common
flue
(Fig.
4).



Please
don’t
install
the
heater
in
places
where
special
chemicals
are
used,
such
as
the
laundries


or
factories
etc.,
otherwise
it
may
cause
rusting,
shorten
the
lifetime
of
the
heater,
or
prevent

normal
working.
(Fig.
5)



Don’t
install
the
heater
above
the
gas
stoves
or
other
heat
sources.
(Fig.
6)



The
 gas
water
heater
should
be
kept
away
from
the
combustible
materials
with
the
distance


shown
in
Fig.
7
at
least.



 When
 the
 installation
 parts'
 materials
 are
 combustible
 or
 flammable
 should
 be
 used


frame‐proof
board
to
isolate,
heat‐resistant
plate
and
wall
gap
should
be
greater
than
10mm,and


the
size
of
heat
plate
should
be
larger
than
water
heater
shell
for
10mm.
(Fig.
8)


Fig.
7
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 Fig.
8



The
electric
wires
and
electric
equipment
are
not
allowed
to
be
placed
on
the
top
of
the
gas


water
 heater.
 The
 horizontal
 distance
 between
 the
 gas
 water
 heater
 and
 other
 electric

equipment
should
be
more
than
400mm.
 



The
power
socket
must
have
a
reliable
ground
wire
to
improve
safety.
In
order
to
reduce
the


number
 of
 times
 of
 plugging,
 it
 is
 better
 to
 use
 a
 socket
 with
 a
 switch.
 Whenever
 the
 water

heater
finishes
working,
please
switch
it
off
to
avoid
being
electrified
in
a
long
term.
The
power

supply
socket
should
not
be
installed
in
the
moist
environment.



 The
 socket
 should
 be
 installed
 at
 the
 side
 of
 the
 product,
 and
 never
 be
 installed
 below
 the


machine
 or
 the
 place
 with
 splashes,
 near
 the
 heat
 source,
 in
 exposure
 to
 sun
 and
 rain,
 or
 the

place
where
it
is
not
easy
to
control.



 The
 installation
 place
 of
 socket
 must
 be
 far
 away
 from
 the
 spraying
 space,
 so
 as
 to
 avoid


Содержание MINI 12 BF ErP

Страница 1: ...TIC INSTANTANEOUS GAS WATER HEATER USER S MANUAL MINI 12 BF ErP Read the technical instruction before installing the appliance Read the user s instruction before lighting the appliance Cod 6328403 09...

Страница 2: ...d operating and keep for future reference Contents Special Advice 2 Features Benefits 2 Specifications 4 Parts Name 7 Installation 9 Using Methods 14 Safety Cautions 18 Maintenance 21 Trouble Shooting...

Страница 3: ...Control for Automatic Constant Temperature of Outlet Water This function is to monitor the outlet water temperature by a temperature sensor and to transfer the information to the micro computer so th...

Страница 4: ...eck protection flame out protection over heat protection accidental power cut protection fan breakdown protection over electric load protection electric leakage protection over wind pressure protectio...

Страница 5: ...sure Pw 10bar Min water pressure Pw 0 2bar Electrical power supply 220VAC 50Hz Electric power 33W Degree of electrical protection IPX4 Ignition method Water Control Automatic Pules Ignition Destinatio...

Страница 6: ...Parts Name Fig 1 The dimension information is for reference only Please refer to the actual product...

Страница 7: ...Fig 2 Unit mm The dimension information is for reference only Please refer to the actual product...

Страница 8: ...aller should be called on to install and adjust the appliance where appropriate This product is prohibited to use this gas water heater when flue pipe has not been installed correctly according to ins...

Страница 9: ...tant plate and wall gap should be greater than 10mm and the size of heat plate should be larger than water heater shell for 10mm Fig 8 Fig 7 Fig 8 The electric wires and electric equipment are not all...

Страница 10: ...e water heater vertically on the upper bolt without inclination and tighten the lower holes with expansion bolts Fig 9 Unit mm 2 Installation of water and gas pipes Fig 10 It can be used when the flue...

Страница 11: ...ater piping throughout your structure may be other than copper we recommend that copper piping be used for at least 0 92 m before and after the heater follow local codes Keep water inlet pipe to no le...

Страница 12: ...lue duct is the shorter the better The flue duct end should have a 20 downward inclination Fig 11 so as to let the condensing water flows out 4 The distance between the flue duct and the combustible m...

Страница 13: ...lbow equivalent 1m straight pipe 3 The distance between the flue duct and the combustible materials should be more than 150mm If the flue duct needs to get through the combustible materials or wall it...

Страница 14: ...Using Methods 1 Display Function instruction Display content instruction Touch button instructions...

Страница 15: ...water is needed you should press ON button Turn off the water valve and water heater stops working but the fan still blows the combustion chamber for several seconds The machine will show the tempera...

Страница 16: ...f saving mode after calculation by microcomputer automatically adjust the amount of gas supply compared other modes more economical by water heater gas consumption not only save gas but also can guara...

Страница 17: ...d is automatically cleared For example when the query information display Water production 180m represents a total cumulative amount of water heater 180m When real time gas consumption information sho...

Страница 18: ...ns 3 if a valve is installed on the hot water circuit open it If there is a control valve 4 at the hot water outlet please open it Turn the drain valve 5 and take off replace it after the residual wat...

Страница 19: ...e gas in different place must not be used Always check the gas pipe and change the pipe every year to avoid gas leakage due to cracking If the flame goes unsteadily stop using the water heater and con...

Страница 20: ...rbon every half year to ensure the combustion product discharges smoothly The heater must be installed vertically if inclined it will make the flame touch the heat exchanger and cause the monoxide to...

Страница 21: ...o low and the hot water volume is so high so that it exceeds the heater s heating power the outlet water will be not hot enough please reduce the water volume In order to ignite immediately the fan in...

Страница 22: ...in gas valve widely There is air in the gas pipe Constantly continue to turn on the water supply control valve High Supply gas pressure inappropr iate Low Contact the technician to check the gas sourc...

Страница 23: ...e and valve unplug the power plug and contact the after sales service Error Code Explanation 01 Inlet water temperature sensor breaks down 10 Detect a flame signal through pre check 11 Ignition fails...

Страница 24: ...Electrical diagram If change No special advice...

Страница 25: ...Conversion instructions...

Страница 26: ...ype parameter settings 4 Model selection After gas type is selected press On Off key to both confirm the selection and enter the next selection interface The F that blinks on the display means that yo...

Страница 27: ...hether the seal ring on gas control system assembly is fixed well 2 Check the airproof of finished product ensure no gas leakage 3 After finish replacing the conversion kits replace the corresponding...

Страница 28: ...Fonderie Sime S p A Via Garbo 27 37045 Legnago VR Telefono 39 0442 631111 Fax 39 0442 631292 www sime it...

Отзывы: