background image

 

Gas
accident
prevention



Check
if
the
flame
of
burner
is
out
after
use
and
do
not
forget
to
turn
off
the
gas
valve
(Fig.
15)


and
power.



Always
check
the
gas
connectors
for
gas
leakage
with
soapsuds.
If
any
gas
leakage
is
detected,


open
 the
 room
 windows
 and
 doors.
 At
 that
 moment,
 do
 not
 ignite
 or
 operate
 the
 switch
 of

electric
appliances
or
plugs
because
the
flame
or
electric
spark
can
result
in
explosive
accidents.

(Fig.
16)



Heaters
must
use
the
gas
type
which
the
heater
is
designed
to
use,
different
type
of
gas
or
the


same
gas
in
different
place
must
not
be
used.



Always
check
the
gas
pipe
and
change
the
pipe
every
year
to
avoid
gas
leakage
due
to
cracking.



 If
 the
 flame
 goes
 unsteadily,
 stop
 using
 the
 water
 heater
 and
 contact
 the
 qualified
 service


facility
for
repair
or
adjustment.


Fig.
15
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 Fig.16


 

Fire
prevention



Do
not
leave
the
water
heater
unattended
whilst
still
in
operation.



In
case
of
power
failure
or
water
failure,
turn
off
the
gas
valve
and
water
inlet
valve.



Do
not
place
towels
or
clothes
on
top
of
the
water
heater.
(Fig.
17)



Do
not
store
inflammables,
explosives
or
volatiles
near
the
water
heater.
(Fig.
18)



Never
incline
the
gas
tank
or
turn
it
upside
down,
the
fluid
gas
is
easy
to
flow
into
the
heater


and
cause
fires.












 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 Fig.17
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 Fig.18


Содержание MINI 12 BF ErP

Страница 1: ...TIC INSTANTANEOUS GAS WATER HEATER USER S MANUAL MINI 12 BF ErP Read the technical instruction before installing the appliance Read the user s instruction before lighting the appliance Cod 6328403 09...

Страница 2: ...d operating and keep for future reference Contents Special Advice 2 Features Benefits 2 Specifications 4 Parts Name 7 Installation 9 Using Methods 14 Safety Cautions 18 Maintenance 21 Trouble Shooting...

Страница 3: ...Control for Automatic Constant Temperature of Outlet Water This function is to monitor the outlet water temperature by a temperature sensor and to transfer the information to the micro computer so th...

Страница 4: ...eck protection flame out protection over heat protection accidental power cut protection fan breakdown protection over electric load protection electric leakage protection over wind pressure protectio...

Страница 5: ...sure Pw 10bar Min water pressure Pw 0 2bar Electrical power supply 220VAC 50Hz Electric power 33W Degree of electrical protection IPX4 Ignition method Water Control Automatic Pules Ignition Destinatio...

Страница 6: ...Parts Name Fig 1 The dimension information is for reference only Please refer to the actual product...

Страница 7: ...Fig 2 Unit mm The dimension information is for reference only Please refer to the actual product...

Страница 8: ...aller should be called on to install and adjust the appliance where appropriate This product is prohibited to use this gas water heater when flue pipe has not been installed correctly according to ins...

Страница 9: ...tant plate and wall gap should be greater than 10mm and the size of heat plate should be larger than water heater shell for 10mm Fig 8 Fig 7 Fig 8 The electric wires and electric equipment are not all...

Страница 10: ...e water heater vertically on the upper bolt without inclination and tighten the lower holes with expansion bolts Fig 9 Unit mm 2 Installation of water and gas pipes Fig 10 It can be used when the flue...

Страница 11: ...ater piping throughout your structure may be other than copper we recommend that copper piping be used for at least 0 92 m before and after the heater follow local codes Keep water inlet pipe to no le...

Страница 12: ...lue duct is the shorter the better The flue duct end should have a 20 downward inclination Fig 11 so as to let the condensing water flows out 4 The distance between the flue duct and the combustible m...

Страница 13: ...lbow equivalent 1m straight pipe 3 The distance between the flue duct and the combustible materials should be more than 150mm If the flue duct needs to get through the combustible materials or wall it...

Страница 14: ...Using Methods 1 Display Function instruction Display content instruction Touch button instructions...

Страница 15: ...water is needed you should press ON button Turn off the water valve and water heater stops working but the fan still blows the combustion chamber for several seconds The machine will show the tempera...

Страница 16: ...f saving mode after calculation by microcomputer automatically adjust the amount of gas supply compared other modes more economical by water heater gas consumption not only save gas but also can guara...

Страница 17: ...d is automatically cleared For example when the query information display Water production 180m represents a total cumulative amount of water heater 180m When real time gas consumption information sho...

Страница 18: ...ns 3 if a valve is installed on the hot water circuit open it If there is a control valve 4 at the hot water outlet please open it Turn the drain valve 5 and take off replace it after the residual wat...

Страница 19: ...e gas in different place must not be used Always check the gas pipe and change the pipe every year to avoid gas leakage due to cracking If the flame goes unsteadily stop using the water heater and con...

Страница 20: ...rbon every half year to ensure the combustion product discharges smoothly The heater must be installed vertically if inclined it will make the flame touch the heat exchanger and cause the monoxide to...

Страница 21: ...o low and the hot water volume is so high so that it exceeds the heater s heating power the outlet water will be not hot enough please reduce the water volume In order to ignite immediately the fan in...

Страница 22: ...in gas valve widely There is air in the gas pipe Constantly continue to turn on the water supply control valve High Supply gas pressure inappropr iate Low Contact the technician to check the gas sourc...

Страница 23: ...e and valve unplug the power plug and contact the after sales service Error Code Explanation 01 Inlet water temperature sensor breaks down 10 Detect a flame signal through pre check 11 Ignition fails...

Страница 24: ...Electrical diagram If change No special advice...

Страница 25: ...Conversion instructions...

Страница 26: ...ype parameter settings 4 Model selection After gas type is selected press On Off key to both confirm the selection and enter the next selection interface The F that blinks on the display means that yo...

Страница 27: ...hether the seal ring on gas control system assembly is fixed well 2 Check the airproof of finished product ensure no gas leakage 3 After finish replacing the conversion kits replace the corresponding...

Страница 28: ...Fonderie Sime S p A Via Garbo 27 37045 Legnago VR Telefono 39 0442 631111 Fax 39 0442 631292 www sime it...

Отзывы: