2.10.1
Electrical panel
(fig. 12)
Disconnect the electric power supply before
performing any work
.
Remove the three screws (9) locking the
control panel in place and pull the panel
forward until it can be tilted downward.
To access the components of the electrical
panel, unscrew the four screws holding
the protective guard in place (6).
2.10.2 Room stat
connection
(fig. 12)
To gain access to connector
“TA”
, remove
the control panel cover (7) and connect the
room stat to the terminals 10-11 after
having removed the jumper.
The thermostat or timer-thermostat,
recommended for better room tempera-
ture control, must be class II as specified
by standard EN 60730.1 (clean contact).
79
4
1
2
3
5
6
7
8
9
Fig. 12
KEY
1
Thermomanometer
2
Time programmer seat
3
Rotary switch
4
Main PCB
5
Earth faston
6
Control panel protection
7
Cover (TA)
8
Connector (TA)
9
Fixing screw
ATTENTION: After having removed the three screws,
take out the panel to tilt it downward.