68
in the kit code 8089904, pushing it
home.
Now the extension or the curve can be fit-
ted into the special seat in order to comple-
te the aspiration pipe (no washer or sealant
is necessary).
2.8.2
Outlet systems (fig. 9)
The diagrams in fig. 9 illustrate a number
of examples of different types of separate
outlets.
2.9
FORCED EXHAUST (Type B22P-52P)
Comply with the following requirements
during installation:
– Insulate the exhaust pipe and install a
condensation collection system at the
base of the vertical pipe.
max 0,5 m
max 0,5 m
C12
B52
1
4
9
C52
B52
C32
C42
3
2
11
10
C82
B22
6
5
6
12
3
11
10
3
7
1
8
3
1
3
2
3
3
2
1
3
2
3
6
3
1
8
3
KEY
1
Separate flue kit code 8089904
2a
90° elbow MF (n° 6) code 8077410
2b
90° elbow MF with intake code 8077407
2c
Isolated 90° elbows MF code 8077408
3a
Extension L. 1000 (n° 6) code 8077309
3b
Insulated extension L. 1000 code 8077306
3c
Extension L. 500 (n° 6) code 8077308
3d
Extension L. 135 with intake code 8077304
4
Outlet terminal code 8089501
5
Int.-est. ring kit code 8091500
6
Intake terminal code 8089500
7
45° elbow MF (n° 6) code 8077411
8
Condensation outlet L. 135 code 8092800
9
Doubler fitting code 8091400
10
Tile with articulated joint code 8091300
11
Roof outlet terminal L. 1390 code 8091201
12
Tee condensation outlet code 8093300
Fig. 9
IMPORTANT: In type C52 the outlet and inlet flues must not come out on opposite walls.
CONFIGURATION C62:
discharge and aspiration is by means of pipes available on sale and certified separately (the pressure loss in the
ducts must be calculated according to the Standard UNI EN 13384)
a
b
5
ATTENTION: The three seats fore-
seen on the diaphragm allow for
fitting the air intake vent in only
one position (the enumeration of
the sectors faces inwards).
Fig. 8/b