25
8.12 Connecting the flue
8.12.1 Flue Terminal Positions
f
c
n
k
k
j
j
j
h
h
e
T
e
h
T
g
P
w
d
b
d
T
g
c
a
M
I
Door
Fig. 23
DESCRIPTION
Brava Slim HE R
Min. Clearance (mm)
Flue terminal
T
Mechanical air inlet
I
Gas meter
M
Electricity meter of fuse box
P
Shaded area indicates prohibited area
Below eaves, balconies and other projections (Appliances over 50MJ/h)
a
300
From the ground, above a balcony or other surface
b
300
From a return wall or external corner
c
300
From a gas meter
d
1000
From an electricity meter or fusebox/breaker panel
e
500
From a drain pipe or soil pipe
f
75
Horizontally from any building structure or obstruction facing a flue terminal
g
500
From any other flue terminal, cowl or combustion air intake
h
300
Horizontally from any opening window, door, non-mechanical air inlet or other opening into a building
with the exception of sub-floor ventilation
j
300
From a mechanical air inlet including a spa blower.
k
1000
Vertically below an opening window, non-mechanical air inlet or any other opening into a building with
the exception of sub-floor ventilation
n
500
m
CAUTION
–
Use as a guide only. See AS/NZS5601 for flue design
details.
–
Refer to AS/NZS5601, current version, or local gas
fitting rules for specific locations.
m
CAUTION
– The location of the flue terminal must comply with
the clearances shown on this page. If you are unsure
about clearances not indicated here, in general refer
to AS/NZS 5601, or your local authority.
m
CAUTION
– All measurements are the minimum clearances
required.
– Terminals must be positioned so to avoid combustion
products entering the building.
– When the installer installs the flue through a
wall, the wall must be adequately sealed and the
hole must not affect the building structure or fire
resistance.
– Install a fire proof back board if installing on
combustible surfaces.
– The fixing method and the wall structure must be
sufficient to hold the weight of the boiler.
Содержание Brava Slim HE 20 R i
Страница 4: ...4 ...
Страница 42: ...42 12 EXPLODED VIEWS Brava Slim HE 20 R i Brava Slim HE 40 R i ...
Страница 43: ...43 Brava Slim HE 20 R e Brava Slim HE 40 R e ...
Страница 44: ...44 Brava Slim HE 20 R i Brava Slim HE 20 R e Brava Slim HE 40 R i Brava Slim HE 40 R e ...
Страница 45: ...45 Brava Slim HE 20 R i Brava Slim HE 20 R e Brava Slim HE 40 R i Brava Slim HE 40 R e ...
Страница 46: ...46 Brava Slim HE 20 R i Brava Slim HE 20 R e Brava Slim HE 40 R i Brava Slim HE 40 R e ...
Страница 55: ...55 ...