Fonderie Sime SpA reserves the right to amend all of the product and relative accessories specifications without prior warning.
34
35
TECHNICAL FEATURES OF THE SOLAR BOILER
GLAZED STEEL SOLAR BOILER
1.
Tank: cold-rolled 2.5 mm thick steel with glazed double internal layer, fired at 860°C according to DIN
4753.
2.
External boiler casing: with internal expansion tank: in cold-rolled steel for closed circuit operation, re-
quired in the regions with lower temperature or with higher concentration of salt in the water mains.
3.
Thermal insulation: the ecological, high density expanded polyurethane guarantees minimal heat loss
while maintaining the DHW temperature.
4.
External casing: naval aluminium alloy / pre-painted galvanised steel.
5.
Cathodic protection: 2 magnesium anodes Ø22x300 mm/ 200 g and Ø26x500 mm/ 500 g for an efficient
protection against corrosion and limescale deposits caused by the electrolytic reactions.
6.
Large circular flange: innovative and elegant design to easily clean from limescale, quickly replace the
anode and immediately access the electric components.
7.
Flexible gasket: non-toxic silicone single piece preventing contact of water with flange. purposely made to
resist to high temperatures.
8.
Electric heater: classified according to the local regulations of the destination country (Optional for the
use of electricity as auxiliary energy source). Conform with Standards EN 60335-1 and EN60335-2-21, all
electrical components are EC marked.
9.
Adjustable automatic thermostat: with bipolar protection with auxiliary safety. All electrical parts are EC
marked according to Standards EN 603335-1 and EN 60335-21.
10.
Protective covering: designed to guarantee electric components' ventilation and protection against at-
mospheric agents.
11.
Cold water inlet: male threaded brass fitting 1/2” BSP and 8 bar safety valve.
12.
DHW outlet: male threaded fitting 1/2" BSP.
13.
Casing inlet: male threaded fitting 3/4” BSP.
14.
Casing outlet: closed circuit filling point: male threaded fitting 3/4" BSP.
15.
Safety valve connection location 1.5 bar or 2.5 bar: male threaded fitting 1/2” BSP.
16
Heat exchanger: with female threaded fittings 3/4" BSP, with stainless steel sleeve, large exchange sur-
face to use the heat produced by the central heating systems during the winter (optional).
15
16
14
11
4
3
2
5
9
8
1
7
6
10
12
13
16
Содержание 8500240