19
7.10
Control panel
2
1
Fig. 14
1
FUNCTIONAL BUTTONS
y
If pressed once or more than once for at least 1 second
during normal operation, this button allows the user to
change the boiler operating mode in a cyclical sequence
(Stand-by – Summer – Winter). If the boiler is experienc-
ing a fault which can be reset, it allows boiler operation
to be unblocked. (Note: the "SUMMER" mode is not ap-
plicable to this boiler).
(
In "parameter setting", the user can scroll through the
parameter index (decreasing) by pressing this button.
t
During normal operation, pressing this button displays
the flow temperature set point which can be between 20
and 80°C. In "parameter setting", the user can scroll
through the parameter index (increasing) by pressing
this button.
<
During normal operation, pressing this button allows the
user to reduce the flow temperature set point. In "pa-
rameter setting/display", the user can modify the pa-
rameter setting or value (decreasing) by pressing this
button.
>
During normal operation, pressing this button allows
the user to increase the flow temperature set point. In
"parameter setting/display", the user can modify the
parameter setting or value (increasing) by pressing this
button.
c
Programming connector cover plug.
NOTE:
pressing any one of these buttons for more than 30 sec-
onds generates a fault on the display without preventing boiler
operation. The warning disappears when normal conditions are
restored.
2
DISPLAY
l
“SUMMER”
. The symbol for "Summer" mode is dis-
played. If the symbols
l
and
n
are flashing, this indi-
cates that the chimney sweep function is active.
n
“WINTER”
. This symbol appears when the boiler is oper-
ating in "Winter" mode. If no operating modes have been
enabled both symbols
l
and
n
will be off.
d
“RESET REQUIRED”
. The message indicates that after
having repaired the fault, normal boiler operation can be
restored by pressing the button
y
.
t
“HEATING”
. This symbol lights up during heating oper-
ation or during the "chimney sweep function It flashes
during the selection of the heating set point.
f
“BLOCK” DUE TO NO FLAME
.
F
“FLAME PRESENCE"
.
v
“POWER LEVEL"
. This indicates the power level at which
the boiler is operating.
p
“PARAMETER"
. This indicates that the user may be in
parameter setting/display, or "info" or "counter", or in
"activated alarms" (history).
A
“ALARM"
. This indicates that a fault has occurred. The
number specifies the cause which generated the alarm.
z
“CHIMNEY SWEEP"
. This indicates that the "chimney
sweep function" has been activated.
a
“HEATING SYSTEM PRESSURE"
. Display of heating system
pressure.
E
"ECO", ALTERNATIVE ENERGY SOURCES
. Where active, it
indicates that there is a solar system available.
c
"MAINTENANCE REQUEST"
. If active, it shows it is time to
perform maintenance on the boiler.
m
CAUTION
– Access to the control panel of models
Brava Slim HE
20 R e
and
Brava Slim HE 40 R e
is possible after loos-
ening screw (1) and removing panel (2).
– On completion of the operations, refit the panel on
the control panel and secure fully.
a
b
1
2
Fig. 15
Содержание 8112265
Страница 42: ...42 12 EXPLODED VIEWS Brava Slim HE 20 R i Brava Slim HE 40 R i ...
Страница 43: ...43 Brava Slim HE 20 R e Brava Slim HE 40 R e ...
Страница 44: ...44 Brava Slim HE 20 R i Brava Slim HE 20 R e Brava Slim HE 40 R i Brava Slim HE 40 R e ...
Страница 45: ...45 Brava Slim HE 20 R i Brava Slim HE 20 R e Brava Slim HE 40 R i Brava Slim HE 40 R e ...
Страница 46: ...46 Brava Slim HE 20 R i Brava Slim HE 20 R e Brava Slim HE 40 R i Brava Slim HE 40 R e ...
Страница 55: ...55 ...
Страница 56: ...Fonderie Sime S p A Via Garbo 27 37045 Legnago Vr Tel 39 0442 631111 Fax 39 0442 631292 www sime it ...