5200992 Rev F
30
Power Supply Number Table
Power
Supply
Number
Clean
Bar
LED
Distance
Mode
LED
Hybrid
Mode
LED
Speed
Mode
LED
00
0
0
0
0
01
0
0
0
1
02
0
0
1
0
03
0
0
1
1
04
0
1
0
0
05
0
1
0
1
06
0
1
1
0
07
0
1
1
1
08
1
0
0
0
09
1
0
0
1
10
1
0
1
0
11
1
0
1
1
LED off = 0. LED on = 1.
Adjusting the Power Supply number is typically a
“one time”
operation performed during the set-up of systems with multiple
Power Supplies and a Communication Module.
6.4 Static Bar Operation
A. Operation normally requires only occasional checking of the
system indicators on the power supply.
B. Anticipated changes in the system indicators include a reduction
of output over time. This may occur over several weeks and
ultimately cause the
“Clean Bar” indicator to light. Regular
maintenance will typically prevent activation of the indicator.
C. Unanticipated changes in the system indicators include
activation of the Fault indicator. This would indicate faulty
condition of static bar, power supply or high voltage connections.
See Troubleshooting section.