IQComGeneratorConverter_UM_9752103110_NL_D_GB_F_V1_0
40
5. Installation
Warning:
- Electrical installation, maintenance and repair must only be carried out by a skilled
electrical engineer and in accordance with national and local regulations.
- The CM5 must be properly earthed. Earthing is needed to ensure proper operation of
the equipment and to avoid electrical shocks upon contact.
- Disconnect the power supply before carrying out work on the unit.
5.1. Advance Check
- Check that the equipment is undamaged and that you have received the correct version.
- Check that the details on the packing slip correspond to the details of the product received.
- Check that the voltage shown on the rating plate corresponds to the (mains) voltage you
intend to use.
If you have any problems and/or doubts, please contact Simco-Ion Netherlands or the agent in
your region.
5.2. IQ Com Generator Converter mounting
Place the IQ Com in a visible, easily accessible, stable place on or near the machine and close
to the CM5 Chargemaster.
Note:
- Do not install IQ Com in a dusty or damp environment or in an environment where
chemicals or other corrosive materials are used.
5.3. IQ Com Generator Converter connection
Figure 1, IQ Com front.
Manager IQ Easy
Machine interface / PLC
Pin Name
Cable
colour
(standard)
Pin Name
Cable colour
(standard)
1
+24V DC input
Brown
1
+24V DC output
100 mA max.
Brown
2
Serial (A)
White
2
Analog remote
on/off
White
3
0V / GND
Blue
3
0V / GND
Blue
4
Serial (B)
Black
4
HV OK output
50 mA max.
Black
5
0V / Earth
Yellow/Green or Grey
5
0V / Earth
Yellow/Green or Grey
Chart 1, Manager IQ Easy connector.
Chart 2, Machine interface / PLC connector.