5101153  Rev  D

I-VSE 5000

As the insulated wire approaches the contact within the terminal, a spark should occur 
and arcing should be heard.  If a spark occurs and arcing is heard, then a static bar is the 
cause of the fault.  Otherwise, the power supply is the cause.  If either is faulty, contact  
Simco-Ion Customer Service or your local Simco-Ion Representative.  
If the ion balance is greater than +/- 30 volts:
1. 

Verify line cord is plugged into a properly grounded 3-terminal receptacle.

2. 

Verify  adapters  or  extension  cords  used  with  the  I-VSE  5000  are  all  properly 
installed, are all of 3-terminal type, and are all properly grounded.

3. 

Verify that the front bezel is NOT grounded (and that a ground lead from a balance 
meter, or other instrument, is not attached to the bezel).

4. 

Verify that a known ground is in use or fan guard on back panel of the I-VSE 5000 
is used as a ground point.

5. 

Verify that all conductive surfaces in the air stream are grounded.

Содержание I-VSE 5000

Страница 1: ...I VSE 5000 5101153 Rev D INSTALLATION AND OPERATING INSTRUCTIONS I VSE 5000 Static Neutralizing Blower...

Страница 2: ...Rev D I VSE 5000 TABLE OF CONTENTS 1 Notes and Cautions 1 2 Introduction 2 3 Specifications 3 4 Installation 3 5 Operation 4 6 Troubleshooting 5 7 Maintenance 7 8 Accessories and Parts 8 9 Warranty S...

Страница 3: ...nt failure CAUTION Statements identified with a CAUTION indicate potential safety hazards NOTE This equipment must be correctly installed and maintained Adhere to the following notes for safe installa...

Страница 4: ...nd is available Receipt of equipment 1 Carefully remove the equipment from its carton 2 Inspect contents for damage that may have occurred during shipment If any damage has occurred the local carrier...

Страница 5: ...stream longitudinally and in the same direction as the target material movement to maximize the time the charged surface remains in the air stream 2 Locate blowers after the material has received its...

Страница 6: ...0 4 2 5 4 3 2 5 5 0 6 4 6 3 6 5 2 7 5 8 4 3 6 3 8 7 0 5 5 7 5 9 8 3 6 8 8 5 10 10 0 8 8 10 3 Decay times represent 90 neutralization of a 1000 VDC Plate 1000 V to 100 V at specified distances Decay t...

Страница 7: ...but not over tightened and that the word POWER is oriented to the right side as you face the bezel 6 Energize the power supply if equipped with an ON OFF switch ensure that it is in the ON position 7...

Страница 8: ...ance is greater than 30 volts 1 Verify line cord is plugged into a properly grounded 3 terminal receptacle 2 Verify adapters or extension cords used with the I VSE 5000 are all properly installed are...

Страница 9: ...y of thorough cleanings should be at least once annually If unit is extremely dirty when cleaning increase frequency to quarterly In very dirty environments it may be necessary to thoroughly clean the...

Страница 10: ...8 5101153 Rev D I VSE 5000 8 ACCESSORIES AND PARTS Item Part Number Emitter assembly 10631 001 Filter Kit 10790 Replacement Air Filters pkg of 10 5050974 Portable Floor Stand optional 5050975...

Страница 11: ...ed items This warranty does not apply when the equipment has been tampered with misused improperly installed altered has received damage through abuse carelessness accident connected to improper line...

Страница 12: ...I VSE 5000 5101153 Rev D Simco Ion 2257 North Penn Road Hatfield PA 19440 215 822 6401 800 203 3419 www simco ion com customerservice simco ion com 2011 Simco Ion Printed in the U S A...

Отзывы: