3.  SPECIFICATIONS

Input Voltage

100-240 VAC, 50/60 Hz 

Input Current

0.5A, 55W max (no heater); 3.5A, 420W (with 100-120 VAC heater); 1.9A, 460W (with 

220-240 VAC heater)

Discharge

1

1.0 sec @ 1’ (30 cm) (1000-100V high fan speed)

Balance

0 ±10V

Coverage Area

3’W x 6’L (91 x 183 cm) (effective coverage area is up to 6’ from the blower face)

Ion Emission

Micropulse AC Ionization

Emitters

Stainless Steel emitter points

Controls

Power on/off, fan speed control low/medium/high, emitter point cleaner push button, 

balance adjust, heater on/off (optional)

Indicators

Green POWER on, red FAULT alarm, red FAN STALL alarm

Connectors

IEC AC Power Cord outlet, FMS fault alarm output connector

Air Volume

95 cfm (low), 150 cfm (high fan speed)

Air Velocity

2

620 fpm @ 12”, 435 fpm @ 24”, 325 fpm @ 36”, 265 fpm @ 48” (high fan)

Heated Air Temp

4-5°F (2-3°C) above ambient, measured at 12” (30 cm) in front of blower (optional)

Audible Noise

58 dB (low fan speed), 70 dB (high fan speed) measured at 2’ in front of blower

Cleanroom Class

Meets ISO 14644 Class 6 (Fed Std. 209E Class 1000)

Ozone

<0.05 ppm measured at 1’ (30 cm) in front of the blower

Operating Env

3

Temperature 50-95°F (10-35°C), humidity 30-60% RH, non-condensing

Audible Alarm

Fault and fan stall (optional)

Mounting

Powder-coated steel stand with skid resistant rubber feet

Enclosure

Powder-coated aluminum chassis

Dimensions

14.13”W x 7.2”H x 6.55”D (35.9 x 18.3 x 16.6 cm) with stand

Weight

7 lbs (3.2 kg) with stand

Warranty

2 year limited warranty

Certifications

1. Tested in accordance with ANSI/ESD STM3.1-2015. 
2. Velocity in fpm measured at center line of air stream; all values ±10%.
3.  Will provide specified (to specification) performance when operated in an environment meeting the cleanliness 

requirements for ISO Class 6.

6

Aerostat XC2

5201333 Rev. A

Содержание Aerostat XC2

Страница 1: ...Extended Coverage Ionizing Blower Aerostat XC2 INSTALLATION AND OPERATING INSTRUCTIONS Aerostat XC2 5201333 Rev A...

Страница 2: ...d Placement 7 Power Connections 8 5 OPERATION 9 Operating Environment 9 Controls and LED Indicators 9 Balance 10 Alarms 11 FMS Relay Contact 12 Optional Air Filter 12 6 MAINTENANCE 13 Maintenance Sche...

Страница 3: ...uipment must be correctly installed and properly maintained Adhere to the following notes for safe installation and operation 1 Read instruction manual before installing or operating equipment 2 Only...

Страница 4: ...he effects of wind chill This manual covers the installation operation and maintenance of the Aerostat XC2 Ionizing Blower Figure 1 Extended Coverage Ionizing Blower Model Aerostat XC2 The Aerostat XC...

Страница 5: ...ns an optional feature ordered separately at the time of XC2 purchase available on the XC2 05A models An optional heater for reducing the effects of wind chill an optional feature ordered separately a...

Страница 6: ...ity controlled environment the XC2 will maintain a balance around zero of 10V or less Performance in extreme environments may vary When using the optional fan filter the unit s performance will be red...

Страница 7: ...VAC 50 60 Hz 3 5A 420W max with heater 220 240 VAC 50 Hz 1 9A 460W max with heater CAUTION The use of improper input voltage may result in poor performance or damage to the unit Damage caused to the p...

Страница 8: ...m 48 high fan Heated Air Temp 4 5 F 2 3 C above ambient measured at 12 30 cm in front of blower optional Audible Noise 58 dB low fan speed 70 dB high fan speed measured at 2 in front of blower Cleanro...

Страница 9: ...ithin the intake or outlet grills There are no user replaceable parts inside this blower other than the emitter cartridge and the power fuse Any unauthorized service will void the warranty and may res...

Страница 10: ...t line cords to meet the main power connection plug requirements in many areas Connect the supplied power cord to an appropriate 3 terminal grounded AC power receptacle CAUTION Using a non grounded po...

Страница 11: ...ors Fan Power Power ON the XC2 by setting the FAN power switch on the rear panel to the ON position I The green LED POWER indicator light on the front panel will light and the fan will startup or Fan...

Страница 12: ...ed by the end user before using the blower A Charged Plate Monitor CPM with a standard 6 x6 plate such as the Simco Ion Model 280A is required to monitor the ionizer s balance during the balance adjus...

Страница 13: ...button Condition POWER Green FAN Red FAULT Red FMS Relay Output Ionization Voltage State Power OFF OFF OFF OFF Open OFF Power ON All Ok ON OFF OFF Closed ON Grill Removed ON OFF ON Open OFF HV Fault O...

Страница 14: ...23 Crimp on Pins Molex 02 06 2101 Crimp tool Molex 63811 1000 or 63819 1300 Pin Function 1 Relay Contact 1 2 Relay Contact 2 Table 2 FMS Pinout Designations Figure 8 FMS Relay Contact Connector on Rea...

Страница 15: ...at XC2 is powered off and unplugged Avoid personal injury or damage to the equipment do not perform any maintenance other than those in these instructions There are no user serviceable parts inside th...

Страница 16: ...ng any of the following cleanings be sure the Model Aerostat XC2 is powered off and unplugged DO NOT ATTEMPT TO REMOVE OR INSTALL THE EMITTER CARTRIDGE UNLESS THE BLOWER IS SWITCHED OFF AND DISCONNECT...

Страница 17: ...side of the metal plate Install the emitter grill assembly back into the XC2 while noting the following 1 The emitter assembly side with the emitter wire weld spots should be facing DOWN toward the c...

Страница 18: ...nts are dirty Clean the emitter points FAN Alarm is ON continuously Fan has stopped Check fan guards for any obstructions Fault Alarm is ON continuously Possible HV failure or fan has stopped Contact...

Страница 19: ...g Blower with Heater 91 XC2 xx 05HA Aerostat XC2 Ionizing Blower with Heater and Audible Alarm 33 6002 01 Aerostat XC2 Replacement Emitter Cartridge 33 6003 01 Aerostat XC2 Air Filter Kit 33 6004 01 A...

Страница 20: ...r This number must accompany all returned items This warranty does not apply when the equipment has been tampered with misused improperly installed altered has received damage through abuse carelessne...

Страница 21: ...Simco Ion 2257 North Penn Road Hatfield PA 19440 215 822 6401 800 203 3419 www simco ion com customerservice simco ion com 2022 Simco Ion Printed in the U S A 19 Aerostat XC2 5201333 Rev A...

Отзывы: