Mounting

The Aerostat XC2 comes with a mounting stand preassembled to the blower. The 

mounting stand is designed for a free or fixed position on a tabletop or workbench 

and mounting to a fixed surface. Self-adhesive skid-resistant rubber feet are supplied 

with the blower and installed on the bottom of the stand by the end-user. Holes in 

the base of the stand are provided for securing the XC2 to a fixed location using 

5/16" (8 mm) diameter screw hardware (not provided).
Once the Aerostat XC2 is secured to a surface, the mounting stand can be adjusted 

and locked to the desired position. Loosen, but do not completely remove, the knobs 

on each side of the blower. Tilt the XC2 to the desired position, so the XC2 ionized 

airstream is aimed directly at the target with no intervening grounded objects. 

Re-tighten the knobs to lock the XC2 into place.

Power Connections

The XC2 accepts universal AC input (100-230 VAC 50/60 

Hz single-phase). The XC2 must be grounded for safe and 

proper operation. The XC2 is available with different line 

cords to meet the main power connection plug requirements 

in many areas. Connect the supplied power cord to an 

appropriate 3-terminal grounded AC power receptacle.

CAUTION

 – Using a non-grounded power cord, if used 

improperly, can cause unpredictable XC2 behavior, 

such-as intermittent activation of the XC2's alarm. 

Care must be taken to ensure the XC2's "LINE" and 

"NEUTRAL" AC input is properly connected to the 

"LINE" and "NEUTRAL" of the utility power.

If installing the XC2 Blower in an electrically noisy environment, an additional 

ground connection can be made to the blower using the convenience ground 

terminal located on the blower's rear panel.
A cord clamp is supplied with the blower. 

Use this cord clamp to prevent unwanted 

disconnection of the power cord or protect 

against the power cord's accidental loosening 

due to vibration.
After connecting the power cord to the power inlet 

connector, fit the power cord through the cord 

clamp and secure the clamp to the rear chassis 

panel with the supplied #6 sheet metal screw.

WARNING – Electric Shock Hazard

Do not insert anything within the intake or outlet grills. Electric shock may 

result.

Figure 5. Ground Terminal

Figure 6. Power Cord Clamp

8

Aerostat XC2

5201333 Rev. A

Содержание Aerostat XC2

Страница 1: ...Extended Coverage Ionizing Blower Aerostat XC2 INSTALLATION AND OPERATING INSTRUCTIONS Aerostat XC2 5201333 Rev A...

Страница 2: ...d Placement 7 Power Connections 8 5 OPERATION 9 Operating Environment 9 Controls and LED Indicators 9 Balance 10 Alarms 11 FMS Relay Contact 12 Optional Air Filter 12 6 MAINTENANCE 13 Maintenance Sche...

Страница 3: ...uipment must be correctly installed and properly maintained Adhere to the following notes for safe installation and operation 1 Read instruction manual before installing or operating equipment 2 Only...

Страница 4: ...he effects of wind chill This manual covers the installation operation and maintenance of the Aerostat XC2 Ionizing Blower Figure 1 Extended Coverage Ionizing Blower Model Aerostat XC2 The Aerostat XC...

Страница 5: ...ns an optional feature ordered separately at the time of XC2 purchase available on the XC2 05A models An optional heater for reducing the effects of wind chill an optional feature ordered separately a...

Страница 6: ...ity controlled environment the XC2 will maintain a balance around zero of 10V or less Performance in extreme environments may vary When using the optional fan filter the unit s performance will be red...

Страница 7: ...VAC 50 60 Hz 3 5A 420W max with heater 220 240 VAC 50 Hz 1 9A 460W max with heater CAUTION The use of improper input voltage may result in poor performance or damage to the unit Damage caused to the p...

Страница 8: ...m 48 high fan Heated Air Temp 4 5 F 2 3 C above ambient measured at 12 30 cm in front of blower optional Audible Noise 58 dB low fan speed 70 dB high fan speed measured at 2 in front of blower Cleanro...

Страница 9: ...ithin the intake or outlet grills There are no user replaceable parts inside this blower other than the emitter cartridge and the power fuse Any unauthorized service will void the warranty and may res...

Страница 10: ...t line cords to meet the main power connection plug requirements in many areas Connect the supplied power cord to an appropriate 3 terminal grounded AC power receptacle CAUTION Using a non grounded po...

Страница 11: ...ors Fan Power Power ON the XC2 by setting the FAN power switch on the rear panel to the ON position I The green LED POWER indicator light on the front panel will light and the fan will startup or Fan...

Страница 12: ...ed by the end user before using the blower A Charged Plate Monitor CPM with a standard 6 x6 plate such as the Simco Ion Model 280A is required to monitor the ionizer s balance during the balance adjus...

Страница 13: ...button Condition POWER Green FAN Red FAULT Red FMS Relay Output Ionization Voltage State Power OFF OFF OFF OFF Open OFF Power ON All Ok ON OFF OFF Closed ON Grill Removed ON OFF ON Open OFF HV Fault O...

Страница 14: ...23 Crimp on Pins Molex 02 06 2101 Crimp tool Molex 63811 1000 or 63819 1300 Pin Function 1 Relay Contact 1 2 Relay Contact 2 Table 2 FMS Pinout Designations Figure 8 FMS Relay Contact Connector on Rea...

Страница 15: ...at XC2 is powered off and unplugged Avoid personal injury or damage to the equipment do not perform any maintenance other than those in these instructions There are no user serviceable parts inside th...

Страница 16: ...ng any of the following cleanings be sure the Model Aerostat XC2 is powered off and unplugged DO NOT ATTEMPT TO REMOVE OR INSTALL THE EMITTER CARTRIDGE UNLESS THE BLOWER IS SWITCHED OFF AND DISCONNECT...

Страница 17: ...side of the metal plate Install the emitter grill assembly back into the XC2 while noting the following 1 The emitter assembly side with the emitter wire weld spots should be facing DOWN toward the c...

Страница 18: ...nts are dirty Clean the emitter points FAN Alarm is ON continuously Fan has stopped Check fan guards for any obstructions Fault Alarm is ON continuously Possible HV failure or fan has stopped Contact...

Страница 19: ...g Blower with Heater 91 XC2 xx 05HA Aerostat XC2 Ionizing Blower with Heater and Audible Alarm 33 6002 01 Aerostat XC2 Replacement Emitter Cartridge 33 6003 01 Aerostat XC2 Air Filter Kit 33 6004 01 A...

Страница 20: ...r This number must accompany all returned items This warranty does not apply when the equipment has been tampered with misused improperly installed altered has received damage through abuse carelessne...

Страница 21: ...Simco Ion 2257 North Penn Road Hatfield PA 19440 215 822 6401 800 203 3419 www simco ion com customerservice simco ion com 2022 Simco Ion Printed in the U S A 19 Aerostat XC2 5201333 Rev A...

Отзывы: