5. OPERATION
Operating Environment
Operate the Model Aerostat XC2 in an environment where the relative humidity
is 30-60% (non-condensing). The operating temperature range for the blower is
50-95°F (10-35°C).
The Model Aerostat XC2 will conform to stated performance specifications when
used in an environment that meets the cleanliness limits defined by ISO 14644-
1 Class 6 (Fed Std. 209E Class 1000) and serviced according to an appropriate
maintenance schedule.
Controls and LED Indicators
Fan Power
Power ON the XC2 by setting the FAN power switch on the rear panel to the ON
position ("I"). The green LED POWER indicator light on the front panel will light,
and the fan will startup.
or
Fan Speed Adjustment
The airflow (fan speed) may be adjusted using the Fan Speed slide switch on the
back of the Aerostat XC2. The XC2 Fan can be set to Low, Medium or High.
Alarm
There are two red LED alarm indicators located on the front panel. FAN will
indicate a stalled fan. FAULT will indicate a loss of high voltage at the emitters,
when the emitter cartridge is removed from the blower, or when ionization is out
of balance.
Figure 7. LED Indicator Lights
9
Aerostat XC2
5201333 Rev. A