background image

E

N

SC

3

0

3

 &

 S

C

5

0

3

   

5.1 SCX03 installed on the minus terminal of the

battery

6. Technical specifications SC303 & SC503

SC303

Operating

Voltage range

6–35V

Temperature range

From –20 to +70°C (from –4 to +158°
F)

Power consumption at 12V

Operating

0.8mA

Current measuring range

Per channel

0.01–320A

Accuracy

±0.6%

Resolution

0.01A

Sampling rate

100ms

Maximal current

Continuous

300A

Peak current (<1min)

700A

Peak current (<5min)

400A

Voltage drop at 300A

50mA

Maximal voltage on connections

35V

Voltage inputs

Range

0–75V

Accuracy

±0.2%

Resolution

1mV

Содержание SC303

Страница 1: ...S I M A R I N E SC303 SC503 USERS MANUAL V1 3 EN USER MANUAL V 1 3...

Страница 2: ...w 4 4 Installation 4 4 1 Cables 4 4 1 1 Power cable 5 5 Connecting 5 5 1 SCX03 installed on the minus terminal of the battery 6 6 Technical specifications SC303 SC503 6 7 Troubleshooting 8 7 1 Negativ...

Страница 3: ...s current up to 300A and suitable for maximal power of 3600W at 12V or 7200W at 24V Innovative combination of shunt and tank level module SC503 is a high precision combo shunt for PICO battery monitor...

Страница 4: ...stall the shunt use the supplied voltage cables and find a place no further than 3 m away from the battery battery bank You can fix the shunt with the supplied screws using two holes on the bottom of...

Страница 5: ...t voltage sensing input to a battery terminal 4 Connect the temperature sensor to the shunt and place it near the battery battery bank optional 5 Connect the battery battery bank minus or plus termina...

Страница 6: ...e From 20 to 70 C from 4 to 158 F Power consumption at 12V Operating 0 8mA Current measuring range Per channel 0 01 320A Accuracy 0 6 Resolution 0 01A Sampling rate 100ms Maximal current Continuous 30...

Страница 7: ...0 to 70 C from 4 to 158 F Power consumption at 12V Operating 1 2mA Current measuring range Per channel 0 01 700A Accuracy 0 6 Resolution 0 01A Sampling rate 100ms Maximal current Continuous 500A Peak...

Страница 8: ...he IN terminal on the shunt If this is not the case you can reinstall the shunt or simply switch the IN and OUT terminal via the shunt configuration on the PICO unit 7 2 Shunt is not visible on PICO I...

Отзывы: