When power is applied to ST75F-GS, ST65F-G, ST55F-G with no load connected or under minimum
load connected, neither damage to power supply nor hazards to users will occur.
5.1 No Load Start
The power supply shall operate properly when first applied at normal input voltage and or so maximum
load after 4 hours storage in 0 C environment.
The power supply can operate normally at any altitude between 0 to 10000 feet.
5.2 Cold Start
5. Start Stability
6.1.1 Operating
6.1 Temperature and Humidity
6.2 Altitude
Sweep and resonance search for each of X,Y,Z, axis at the sweep.
RATE of 1/OCTAVE/Min.
6.3 Vibration and Shock
6. Environments
Temperature
Relative Humidity
0 C to 40 C
20 to 90 %
o
o
6.1.2 Storage
Temperature
Relative Humidity
-40 C to 70 C
20 to 95 % noncondensing
o
o
Frequency
5-55-10 Hz
Duration
30 minutes
Amplitude
0.35 mm
o