09
* T1 : Turn on time ( 2 sec. Max.)
* T2 : Rise time (
≦
20mS Max.)
* T3 : Power good turn on delay time ( 100 < T3 < 500 mS )
* T4 : Switch on time (0.5 sec. Max.)
* T5 : Power good turn off delay time ( 1.0 mS Min.) PS-ON/OFF
* T6 : Power hold-on time ( 16 mS Min.)
* Power on-off cycle :
When the power supply is turned off for a minimum of 2.0 sec. and turn on again, the power good signal will
be asserted.
The MTBF of the power should be 100,000 hours min.
10. MTBF
Applying 220Vac for 230V model.
11.1 Input Voltage
Applying 75% loads for the power supply in 45 (+/-5) oC chamber for 4 hours.
11.2 Test Condition
11. Burn-In
The product shall meet requirement for EN61000-3-2 & EN61000-3-3 :1995 standard
of class D, test at 230Vac 50Hz.
12. Harmonics
The power supply with active power factor correction, and meet the EN61000-3-2
standards, The power factor is greater than 0.9 at 230V/50Hz, Max. load.
13. Power Factor
150 mm (W) × 86 mm (H) × 140mm (D)
14. Mechanical Specification
Содержание ST55F-G