12
C. MEASUREMENTS
1. Circuit Power Check
The indicator shall indicate 220 V when the positive and negative
probes (the pole is irrelevant) in the AC voltage range of the
multimeter (while Range: Auto or Range: 100) are contacted with
the pins connected to the power cord of the terminal while power
is supplied to the product.
2. Short Circuit Test for the Power Cord
Switch the multimeter to the short circuit test mode. Contact one
of the probes (the pole is irrelevant) to the probe of the male
socket and the other one to the cord terminal. A continuous
audible signal shall be issued from the multimeter and a fixed
value shall be displayed on the screen in this condition.
Otherwise, the cord is damaged.
3. Short Circuit Test for the Switch Cord
i.
Short Circuit Test for the Switch Lamp Cord
Switch the multimeter to the short circuit test mode. Contact one
of the probes (the pole is irrelevant) to the terminal of the brown
cord of the push button and the other one to the terminal of the
white cord. A continuous audible signal shall be issued from the
multimeter and a fixed value shall be displayed on the screen in
this condition. Otherwise, the cord is damaged
Содержание H10560 015
Страница 1: ...1 EN SERVICE MANUAL H10560 015 H10590 015...
Страница 6: ...6 4 Explanation of the Characters in the Serial Number...
Страница 10: ...10 7 Grounding Cord 8 Lamp Holder...
Страница 25: ...25 12 Wiring Diagram For All Boards...