OPERATION INSTRUCTION

 

 

Before attempting to operate or install this unit carefully read 
and take note of the following safety warnings. 
Failure to comply with these warnings may result in serious 
injury or death. 

Keypad 
Instruction 

Comment 

ON/OFF 

This turns the cooler on or off.  

COOL 

This activates the cooling function. Note that there is a 
delay of 1 minute while the cooling pads are wetted before 
cooling can begin. 
If cooling is not active unit can operate as fan  

WIND SPEED 

Pressing SPEED will select low, medium or high fan speed. 

SWING 

This activates/deactivates swing function. 

TIMER 
Delayed start 

The timer setting can be used to start the cooler after a 
certain number of hours delay. When only the green 
POWER light is on, press TIMER until the number of hours 
delay (1-24) is shown.  When screen 00 indicated timer is 
cancelled. 

TIMER 
Automatic stop 

When the cooler is already going, press timer to set the 
number of hours (1-24) until the machine will automatically 
switch off. When screen 00 indicated timer is cancelled. 

WATER 
SUPPLY 

Use only clean, fresh water. 
Pour water into the water inlet on the right hand side of the 
unit (Do not overfill beyond max capacity). Alternatively, 
attach a hose to the water inlet on the left side for automatic 
filling. Note a pressure reducing valve is recommended for 
high pressure water supplies. 

 

1. All electrical repairs must only be carried out by a suitably qualified 

electrician, after all power is disconnected. 

2. This cooler is not intended for use by children or persons with reduced 

physical, sensory or mental capabilities or lack of experience and knowledge. 

3. Children should be supervised to ensure that they do not play with the 
appliance. 
 

 

Содержание FC400

Страница 1: ...851 144 FC400 NEW ZEALAND 22 Sunshine Avenue Te Rapa Hamilton 2001 New Zealand Telephone 64 07 8496033 Fax 64 07 8496070 www silvannz co nz VICTORIA HEAD OFFICE 244 266 Greens Rd Dandenong South 3175...

Страница 2: ...r to evaporate making the air cool and fresh The circulating water moves down to the reservoir where it is again pumped up through the cooling pads If the hose option is being used supplied as standar...

Страница 3: ...eding machine specifications including overloading impact damage negligence accidental damage or failure to perform recommended maintenance services as specified in the Owner Operator Manual applicabl...

Страница 4: ...MODEL FC400 Max Airflow M3 H 9000 Power supply Frequency V HZ 220 240 50 Power Consumption W 400 Fan Style Axial Water Consumption L H 4 6 Water Tank Capacity L 70 Dimension L W H mm 860x530x14 00 We...

Страница 5: ...ater level in reservoir is low 3 Rinse the reservoir with fresh water and clean prior to use after a period where the cooler has not been in operation 4 Take care when moving the cooler especially whe...

Страница 6: ...CK WHEEL FILL POINT FOR BUCKET SIDE VENT AIR INLET FRONT VENT AIR OUTLET BODY CONTROL PANEL WATER DISTRIBUTOR WATER PIPE SIDE COOLING PAD DUST RESISTANT MESH SCREEN INLET PROTECTIVE GRILL MOTOR BRACE...

Страница 7: ...ntil the number of hours delay 1 24 is shown When screen 00 indicated timer is cancelled TIMER Automatic stop When the cooler is already going press timer to set the number of hours 1 24 until the mac...

Страница 8: ...CONTROL PANNEL REMOTE CONTROL...

Страница 9: ...been removed 2 Clean the pad from the inner side to out side of pad inner side is towards motor Never use any liquid detergent Never use pressurized water as it may cause damage to the pad 3 Unscrew t...

Страница 10: ...t filter is blocked Fan is distorted Main control board failure Check to ensure there is nothing preventing free rotation of the fan Clean the cooling pad Change the fan Change the main control board...

Страница 11: ...SERVICE MAINTENANCE LOG Date Hours of use Notes eg Parts cleaned chlorine bromine tablets used and how many...

Страница 12: ...Greens Rd Dandenong Sth 3175 Australia Telephone 61 03 9215 2700 Facsimile 61 03 9215 2701 www silvan com au SILVAN NEW ZEALAND PTY LTD 22 Sunshine Avenue Te Rapa Hamilton 2001 New Zealand Telephone...