15
Calibration
3. Berries
Application rate
400 l/ha
Travel speed
5 km/hr
Row width
3 m
Spraying pressure
13 Bar
If using 8 nozzles (4/side) with two turned off due to a smaller canopy then each nozzle needs to
deliver 1.25 l/min. From the HCC nozzle chart HCC015 (Yellow) at 13 Bar pressure will give the
desired output. An alternative nozzle would be the HCC02 at approximately 7 Bar to give an
equivalent output.
Calibration Worksheets
The worksheets below can be used to record the results of calibration tests on your sprayer.
Total Application Rate (l/min) =
Application rate (l/ha) x Speed (km/hr) x Row width (m)
600
400 x 5 x 3
600
= 10 l/min
Date of Test: _______________
Application Rate: _______________ litres/ha
Speed of Travel: _______________ km/hr
Row Spacing: _______________ metres
Number of nozzles:
Output per nozzle:
HCC Hollow Cone Nozzles: ____________
Pressure Setting: __________ Bar
Measured Output: _________ litres/min
(from test run)
Output (l/min)
=
Application Rate x Speed x Row Width
600
x x
600
=
= litres/min
Date of Test: _______________
Application Rate: _______________ litres/ha
Speed of Travel: _______________ km/hr
Row Spacing: _______________ metres
Number of nozzles: ____________
Output per nozzle:
HCC Hollow Cone Nozzles:
Pressure Setting: __________ Bar
Measured Output: _________ litres/min
(from test run)
Output (l/min)
=
Application Rate x Speed x Row Width
600
x
600
=
= litres/min