background image

 

 

 

 

Locating Tab & Hub Clamp screw 

 

 

Operation

 

Starting the Sprayer

 

Before  starting  the  sprayer  for  the  first  time 
grease  all  lubrication  points  including  the  PTO 
shafts. Check that the oil  level  in the diaphragm 
pump  is  level  with  the  mark  in  the  viewer  and  if 
necessary  top  up  with  SAE  20W-50  multigrade 
engine  oil.    Ensure  that  the  gearbox  oil  level  is 
correct.  Refer Maintenance section for details. 

 
First  conduct  a  trial  using  clean  water  only  (no 
chemicals)  to  become  familiar  with  the  controls 
and  to  check  that  all  systems  are  functioning 
correctly without leakage.  

  
On 2000L models before filling the tank check that 
the drain valve located in front of LH step is in the 
“pump”’  position,  i.e.  red  handle  facing  forward. 
Then  fill  the  tank  through  the  opening  after 
checking that the basket strainer is  in place and 
clean.  Close  and  rotate  the  lid  to  secure  it  after 
filling. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
On  Supaflo  models  ensure  the  shut  off  valve  in 
the  suction  filter  is  open.  It  is  open  when  the 
yellow cap is turned counter clockwise and closed 
when  it  is  pushed  in  and  turned  clockwise.  It 
automatically closes when the cap is screwed off 
which allows the filter cover to be unscrewed and 
the  element  to  be  removed  for  cleaning  while       
there is fluid in the tank. 

 
 
 
On  1000L  models  check  the  drain  valve  located 
in front of the LH tyre is in the “pump” position, i.e. 
with the red handle placed vertically. Fill the tank 
through the basket strainer then close and secure 
the lid before commencing spraying.   
Check  that  the  fan  gearbox  is  engaged  and  the 
required speed is selected. Never engage the fan 
drive with the tractor engine running  or the  PTO 
engaged.  Moving  the  gearbox  lever  to  the  high 
position  produces  maximum  airflow.  The  low 
position produces less airflow and can be used to 
protect  the  crop  canopy  from  damage.  The 
neutral position enables the pump to be operated 
without the fan for putting chemicals into the tank, 
hand spraying or similar operations. 
 

 

The  fan  incorporates  a  centrifugal  clutch  which    
protects the gearbox and driveline if the PTO is 
engaged rapidly. The sprayer should always be 
operated  at  540  PTO  rpm  to  ensure  correct 
operation of the centrifugal clutch and to prevent 
its premature wear.  
With electric valve controls, switch the Master 
valve to the “Off” position before engaging the 
PTO. This places the pump into by-pass mode 
and closes the outlet valves to the spray 
nozzles on either side of the sprayer.  
Engage the PTO slowly and allow the sprayer to 
run in by-pass mode. Once the pump is primed 
increase the tractor speed to 540 PTO rpm. 
 
Flip the required number of spray nozzles to the 
open position. Refer to the Calibration section for 
information on nozzles and jet selection. 

 

   

DRAIN VALVE 

Red Valve 
Handle 

SUCTION FILTER - SUPAFLO MODELS

 

Shut Off Valve 

GEARBOX SELECTION LEVER (L) 

Содержание DEC101213P

Страница 1: ...Operator s Manual MANSLV 2 August 2021 Trailed Oktopus Air Assist Sprayers...

Страница 2: ...ails of your sprayer here for future reference when discussing service with your Silvan dealer ordering parts or making a warranty claim SERIAL NUMBER _____________________________ MODEL _____________...

Страница 3: ...ranty period begins on the date the product is delivered to the first retail purchaser for a period of 12 months This Warranty Covers Only conditions resulting directly from defects in workmanship or...

Страница 4: ...neutral position Max Speed at 540 PTO rpm 2 700 rpm Air speed 450mm dia fan 80 m sec Capacity 450mm dia fan 14 000 m3 hr Controls Cab mounted control box with master on off switch left right section...

Страница 5: ...safe working loads and relevant tractor safety instructions Exercise extreme care when operating in hilly or uneven terrain to ensure proper stability Adjust the sprayer wheel track for maximum stabil...

Страница 6: ...safety decals before operating the sprayer Failure to comply with these warnings could result in serious injury or death Safety decals should be kept clean and legible at all times If any decals are...

Страница 7: ...g of the safety decals shown on the previous pages is given below Before operating the sprayer read all safety warning decals Failure to comply with these warnings could result in serious injury or de...

Страница 8: ...th but not less than 150mm in all possible operating positions and there must be at least 25mm telescopic movement remaining at the minimum operating length refer Fig 2 The length of the sprayer drawb...

Страница 9: ...ble to be adjusted Adjusting the Air Diffusers The fan unit has multiple diffusers Silvan units are fitted with a 5 5 configuration All of the diffusers are fully adjustable in width height and angle...

Страница 10: ...the LH tyre is in the pump position i e with the red handle placed vertically Fill the tank through the basket strainer then close and secure the lid before commencing spraying Check that the fan gea...

Страница 11: ...gain and repeat for the remaining sections The sprayer is then adjusted correctly Adding Chemicals Chemicals can be added to the tank through the top opening or more safely and conveniently by use of...

Страница 12: ...s time the by pass flow and the venturi agitator will thoroughly mix the solution Note This is the only operation permitted with the sprayer running while the operator is off the tractor Emptying and...

Страница 13: ...ozzle cap A nylon gasket part number MA3 03 is fitted over the HCC nozzle then pushed into the cap There is no nozzle body filter used with HCC nozzles Nozzle output can be varied by fitting different...

Страница 14: ...oplets produced at higher pressures STEP 2 Total Output Required Calculate the total spray output required in litres per minute l min using the following formula Check that the calculated output does...

Страница 15: ...output An alternative would be to use HCC025 Red at 7 Bar pressure to give the equivalent output 2 Orchard Fruits Application rate 1200 l ha Travel speed 4 km hr Row width 4 5 m Spraying pressure 15 B...

Страница 16: ...Row width m 600 400 x 5 x 3 600 10 l min Date of Test _______________ Application Rate _______________ litres ha Speed of Travel _______________ km hr Row Spacing _______________ metres Number of noz...

Страница 17: ...ontroller Arag Bravo automatic rate controller in lieu of standard electric valves Ensures application rate remains constant with any minor changes in ground speed Displays and records application rat...

Страница 18: ...level in the viewer daily and if necessary top up with SAE 20W 50 multigrade engine oil The oil must reach the mark on the side of the oil level viewer Gearbox Check the oil level every 50 hours and...

Страница 19: ...ce as necessary Check the air pressure in the surge chamber on the pump The air pressure behind the surge chamber s diaphragm smoothes out the pulsations in fluid flow and should be set in accordance...

Страница 20: ...left open Supaflo models Pressure filter flushing valve left open Fan noisy and or vibrating Gearbox bearings worn Fan damaged or out of balance Tractor PTO incorrectly installed Hitch point and PTO g...

Страница 21: ...supply and check operation Is the customer satisfied with the sprayer s performance TANK Is the customer fully instructed in the sprayer s service and maintenance Clean contaminants from tank requirem...

Страница 22: ...21 SILVAN AUSTRALIA PTY LTD ABN 48 099 851 144 68 Atlantic Drive Keysborough VIC 3173 Australia Telephone 1300 745 826 Facsimilie 1800 745 826 www silvan com au...