![Silicon Laboratories Si446 Series Скачать руководство пользователя страница 50](http://html1.mh-extra.com/html/silicon-laboratories/si446-series/si446-series_manual_1271734050.webp)
A N 6 2 5
50
Rev. 0.1
3.5.12. FREQ_CONTROL_INTE
Summary: Frac-N PLL integer number.
Purpose:
Fractional-N PLL integer number defined by the modem calculator. See datasheet for frequency equation for manual
calculation.
Property: 0x4000
Default: 0x3C
Fields:
inte[6:0] - default:0x3C
Range: 0–127
Register View
3.5.13. FREQ_CONTROL_FRAC_2
Summary: Byte 2 of Frac-N PLL fraction number.
Purpose:
Fractional-N PLL fraction number defined by the modem calculator. See data sheet for frequency equation for manual
calculation.
Property: 0x4001
Default: 0x08
Fields:
frac_2[2:0] - default:0x0
Range: 0–7
Register View
FREQ_CONTROL_INTE
7
6
5
4
3
2
1
0
0
INTE[6:0]
0
0x3C
FREQ_CONTROL_FRAC_2
7
6
5
4
3
2
1
0
0x01
frac_2[2:0]
0x01
0x0
Содержание Si446 Series