A N 6 2 5
100
Rev. 0.1
3.5.104. PA_MODE
Summary: PA operating mode and groups.
Purpose:
Specify PA mode and HPA/MPA groups
Property: 0x2200
Default: 0x10
Fields:
PA_GROUP[3:0] - default:0x4 ODEV group and unit configuration.
0 = No groups on.
1 = Reserved
2 = Set for Si4464/63/62
3 = Reserved
4 = Reserved
5 = Reserved
6 = Set for Si4460
7 = Reserved
8 = Set for Si4461.
PA_MODE[1:0] - default:0x0 PA mode.
0 = Switch, for Square Wave or Class E
1 = Switch Current - 13 dBm
2 = Switched Current - 10 dBm
Register View
3.5.105. PA_PWR_LVL
Summary: PA Power Level Configuration
Purpose:
Adjusts the TX power level in fine resolution.
Property: 0x2201
Default: 0x7F
Fields:
DDAC[6:0] - default:0x7F
Range: 0-127
Register View
PA_MODE
7
6
5
4
3
2
1
0
0x0
PA_GROUP[3:0]
PA_MODE[1:0]
0x0
0x4
0x0
PA_PWR_LVL
7
6
5
4
3
2
1
0
0
DDAC[6:0]
0
0x7F