Reset value = xxxxxxxx
Reset value = xxxxxxxx
Reset value = 00000001
Register 17h. Wake-Up Timer Value 1
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
wtm[15:8]
Type
R
Bit
Name
Function
7:0
wtm[15:8]
Wake Up Timer Current Mantissa (M) Value*.
*Note:
The period of the wake-up timer can be calculated as T
WUT
= (4 x M x 2
R
) / 32.768 ms.
Register 18h. Wake-Up Timer Value 2
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
wtm[7:0]
Type
R
Bit
Name
Function
7:0
wtm[7:0]
Wake Up Timer Current Mantissa (M) Value*.
*Note:
The period of the wake-up timer can be calculated as T
WUT
= (4 x M x 2
R
) / 32.768 ms.
Register 19h. Low-Duty Cycle Mode Duration
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
ldc[7:0]
Type
R/W
Bit
Name
Function
7:0
ldc[7:0]
Low-Duty Cycle Mode Duration (LDC)*.
If enabled, the LDC will start together when the WUT is supposed to start, and the dura-
tion of the LDC is specified by the address 19h and the equation that goes with it. In order
for the LDC to work, the LDC value has to be smaller than the M value specified in regis-
ters 15h and 16h.
LDC = 0 is not allowed here. Write at least decimal 1.
*Note:
The period of the low-duty cycle ON time can be calculated as T
LDC_ON
= (4 x LDC x 2
R
) / 32.768 ms. R is the same
as in the wake-up timer setting in "Register 14h. Wake-Up Timer Period 1".