
4.2 General Operating Conditions
This table specifies the general operating temperature range and supply voltage range for all supplies. The minimum and maximum
values of all other tables are specifed over this operating range, unless otherwise noted.
Table 4.2. General Operating Conditions
Parameter
Symbol
Test Condition
Min
Typ
Max
Unit
Operating ambient tempera-
ture range
T
A
-I temperature grade
-40
—
+125
° C
VDD Supply Voltage
V
DD
1.71
3.0
3.8
V
IOVDD operating supply volt-
age (All IOVDD pins)
V
IOVDD
1.71
3.0
3.8
V
HCLK and Core frequency
f
HCLK
—
—
80
MHz
—
—
50
MHz
—
—
39
MHz
PCLK frequency
f
PCLK
—
—
50
MHz
EM01 Group A clock fre-
quency
f
EM01GRPACLK
—
—
80
MHz
HCLK Radio frequency
f
HCLKRADIO
38
38.4
40
MHz
Note:
1. Flash wait states are set by the MODE field in the MSC_READCTRL register. RAM wait states are enabled by setting the RAMW-
SEN bit in the SYSYCFG_DMEM0RAMCTRL register.
MGM210P Wireless Gecko Multi-Protocol Module Data Sheet
Electrical Specifications
silabs.com
| Building a more connected world.
Rev. 1.2 | 11