Graphics
007-5483-001
63
•
Use the Supermicro
xgicfg
command from a DOS-bootable thumb-drive
image
•
Use in-band
ipmitool
from the operating-system prompt
•
Use the
ipmitool
command or the AOC-SIMSO web interface to communicate
with the BMC
Caution:
The DEFAULTP.EXE command resets all BMC network settings to
their default setting.
•
If the BMC does not respond, you can reset it to default values with the SuperMicro
DEFAULTP.EXE command from a DOS-bootable thumbdrive image
Power
Use the following tools and techniques to troubleshoot the power components on the
SGI Virtu VN200:
•
Check the power supply status LEDs. Each power supply has an green LED that
illuminates when DC power is present. When a supply fails, the PWR FAIL LED on
the control panel illuminates and the power-supply status LED does not illuminate.
•
Use the IPMI web interface, the
ipmitool
command, or the power-supply LEDs to
determine which supply has failed
•
Hot-swap the failing supply without powering the node down (if the node has a
redundant power supply) to perform fault isolation
Cooling
If a fan or temperature fault occurs, the red ALERT LED on the control panel illuminates.
•
Use
ipmitool
or the IPMI web interface to determine which fan has failed
•
Remove the graphics node from the rackmount shelf and open the side access panel
to replace the failed fan
Содержание Virtu VN200
Страница 1: ...SGI Virtu VN200 Graphics Node Hardware User s Guide 007 5483 001 ...
Страница 3: ...007 5483 001 iii Record of Revision Version Description 001 April 2008 Original printing ...
Страница 4: ...iv 007 5483 001 ...
Страница 12: ...xii 007 5483 001 ...
Страница 36: ...20 007 5483 001 SGI Virtu VN200 Overview ...
Страница 58: ...42 007 5483 001 System Features ...
Страница 108: ...92 007 5483 001 System Procedures ...