48
007-5841-001
6: Basic Troubleshooting and Chassis Service
Power Supply Failure
If either of the two power supply modules fail, the other module will take the full load and allow
the system to continue operation without interruption. The PWR Fail LED will illuminate and
remain on until the failed unit has been replaced. The power supply units have a hot-swap
capability, meaning you can replace the failed unit without powering down the system, see
Figure 6-4 on page 49
for an example.
Removing/Replacing a Power Supply
You do not need to shut down the system to replace a failed power supply unit. The backup power
supply module will keep the system up and running while you replace the failed unit. Replace with
the same model.
Removing the Power Supply
1.
First unplug the AC power cord from the failed power supply module.
2.
Depress the locking tab on the power supply module.
3.
Pull it straight out using the rounded handle.
Installing a New Power Supply
1.
Replace the failed hot-swap unit with another identical power supply unit.
2.
Push the new power supply unit into the power bay until you hear a click.
3.
Secure the locking tab on the unit.
4.
Finish by plugging the AC power cord back into the unit.
Содержание Rackable C2110G-RP5
Страница 1: ...SGI Rackable C2110G RP5 System User Guide 007 5841 001 ...
Страница 3: ...007 5841 001 iii Record of Revision Version Description 001 May 2012 First release ...
Страница 4: ......
Страница 10: ......
Страница 22: ......
Страница 27: ...Install the System into a Rack 007 5841 001 13 Figure 2 2 Separating the Rack Rails ...
Страница 31: ...Install the System into a Rack 007 5841 001 17 Figure 2 5 Installing the Server in the Rack ...
Страница 38: ......
Страница 52: ......
Страница 63: ...Power Supply 007 5841 001 49 Figure 6 4 Power Supply Remove Replace Example ...
Страница 69: ...System Fans 007 5841 001 55 Figure 6 9 Front GPU Fan Assembly Example ...
Страница 76: ......