
007-5841-001
39
Chapter 6
6.
Basic Troubleshooting and Chassis Service
Use the procedures in the first half of this chapter to troubleshoot your system. If you have
followed all of the procedures below and still need assistance, check with your authorized support
organization.
The subsections in the second half of this chapter starting with
“Chassis Service Information” on
page 41
are intended to guide you through basic component remove and replace procedures.
Basic Troubleshooting Procedures
Use the information in the following subsections to remedy basic problems you might encounter
when working with the Rackable C2110G-RP5 server.
If the System Does Not Power Up
If the system will not power up when the front power button is pushed, use the following checklist
to identify common sources for the problem:
•
Make sure that both ends of each system power cable are firmly connected to the power
supply and the corresponding power source(s) or power distribution unit (PDU).
•
Check to see if the power fail LED is lit on the front of the unit. This LED should be off if
the system is operating normally.
•
Check that the LED on each power supply is properly lit. The power supply has one status
LED located on the left side of the front of the power supply. The LED has three states:
–
Dark or off - indicates no AC power present
–
Yellow - AC power is present, the server is not turned on (no DC power)
–
Green - AC power is present and the server is turned on (DC power present)
•
Open the system cover, remove the air shroud and check to make sure that no obvious short
circuits exist between the serverboard and chassis.
Содержание Rackable C2110G-RP5
Страница 1: ...SGI Rackable C2110G RP5 System User Guide 007 5841 001 ...
Страница 3: ...007 5841 001 iii Record of Revision Version Description 001 May 2012 First release ...
Страница 4: ......
Страница 10: ......
Страница 22: ......
Страница 27: ...Install the System into a Rack 007 5841 001 13 Figure 2 2 Separating the Rack Rails ...
Страница 31: ...Install the System into a Rack 007 5841 001 17 Figure 2 5 Installing the Server in the Rack ...
Страница 38: ......
Страница 52: ......
Страница 63: ...Power Supply 007 5841 001 49 Figure 6 4 Power Supply Remove Replace Example ...
Страница 69: ...System Fans 007 5841 001 55 Figure 6 9 Front GPU Fan Assembly Example ...
Страница 76: ......