44
007-5843-002
A: System Specifications
Environmental Specifications
Table A-1 lists allowable ranges for temperature, humidity, and altitude for the server.
Table A-1
Temperature, Humidity, and Altitude Specifications
Attribute
Specification
Rate of Change Constraints
While Product Operating
Temperature
– Up to 1500m (5000ft)
+5
º
C (41
º
F) to +35
º
C (95
º
F)
– 1525m (5000ft) to 3050m (10,000ft)
Reduce max temperature (35
º
C) by 1
º
C per
305m (1000ft) of altitude above 1525m
(5000ft).
Maximum: 10
º
C/hour (18
º
F/hour)
Humidity
20% to 80% Non-condensing
Maximum: 10% relative
humidity/hour
Altitude
3050m (10,000ft)
While Product Power Off
Temperature
+5
º
C (41
º
F) to +45
º
C (113
º
F)
Maximum: 20
º
C/hour (36
º
F/hour)
Humidity
8% to 80% Non-condensing
Altitude
3050m (10,000ft)
While Product Packaged for Shipping
Temperature
-40
º
C (-40
º
F) to +60
º
C (140
º
F)
Maximum: 20
º
C/hour (36
º
F/hour)
Humidity
8% to 80% Non-condensing
Altitude
12,200m (40,000ft)