4: Internal Component Replacement and Upgrades
Installing the 450-Watt Non-Redundant Power Supply
Use the following steps to install a new 450-Watt power supply into the server:
1.
Position the new supply in the chassis so that the rear screw holes are aligned with the holes
in the rear sheetmetal and the front chassis retention bracket.
2.
Use the three screws you removed in step 4 of the instructions “Removing the 450-Watt
Non-Redundant Power Supply” on page 38 to secure the unit inside the server. See
Figure 4-11.
3.
Reconnect the small, medium and large power cable connectors to the outer side of the
power supply, see Figure 4-10 on page 39.
4.
Attach the rear system power cord to the supply and ensure the rocker switch is set to the (
|
)
on position. The system fans should start up and pushing the power button on the front of the
chassis should boot the system.
5.
Replace the top cover and secure it with the two top cover-retention screws. Slide the system
back into the rack as applicable.
Figure 4-11
450-Watt Power Supply Replacement Example