5: Troubleshooting Information
ISS3124-RP2 Server Power Supply LEDs
There is a single bi-color LED (green/amber) to indicate the ISS3124-RP2 server power supply
status.
Table 5-3
describes the different states of the LED.
No Video After Power-On
If the power is on and the system has had adequate time to boot, but there is no video, check all
add-on cards and cables. Tighten or re-plug any loose cable connections. Be sure your monitor is
powered up and switched to the
On
position.
Use the speaker to determine if any beep codes exist. Refer to
Appendix A, “BIOS Error Codes”
for details.
If video output is still absent, check with your system administrator or service provider.
Loss of System Setup Configuration
Make sure that your power supplies are operating properly, see
“No Video After Power-On” on
page 48
for guidelines. An improperly operating power supply may cause the system to lose the
CMOS setup information. If this does not fix the Setup Configuration problem, consult your
system administrator or contact your service organization for repairs.
Table 5-3
ISS3124-RP2 Power Supply LED States
LED State
Power Supply (PS) State
Off
No AC power to any PS.
Green
Output on and Ok.
Green, 1Hz blink
AC present (only 12VSB on). PS off or PS in cold redundant state.
Green, 2Hz blink
PS firmware updating.
Amber
– PS critical event causing a shutdown/failure (OCP, OVP, fan failure) –
AC cord unplugged or AC power lost. A second power supply in parallel
still has AC input power.
Amber, 1Hz blink
PS warning events where the power supply continues to operate (high
temperature, high power, high current, slow fan).
Содержание IS2224
Страница 1: ...SGI NAS ISS3124 RP2 Server and IS2224 JBOD Setup Guide 007 5922 001 ...
Страница 3: ...007 5922 001 iii Record of Revision Version Description 001 October 2013 First release ...
Страница 4: ......
Страница 8: ......
Страница 24: ......
Страница 44: ......
Страница 56: ......
Страница 60: ......
Страница 66: ......
Страница 68: ......
Страница 72: ......