Key Components of ISS3000 3U Servers
007-5721-001
7
Table 1-2
describes the pinouts for the serial connector when Roamer is not installed.
Rear fans
Keep the area behind the fans clear and unobstructed. This
will ensure proper airflow to the components inside the
server chassis.
Serial connector
(RJ-45 management
port)
This port is accessed with an RJ-45 connector. When the
Roamer remote management module is installed, this port
functions as an interface to the module. When the Roamer
remote management module is not installed, the pinout for
the serial connector is as shown in
Table 1-2
.
Table 1-2
Pinouts for the Serial Connector J3
Pin
Name
Description
1
RTS
Request To Send (JP1 “A”)
CTS
Clear To Send (JP1 “B”)
2
DSR
Data Set Ready
3
RxD
Receive Data
4
GND
Ground Return
5
GND
Ground Return
6
TxD
Transmit Data
7
DTR
Data Terminal Ready
8
CTS
Clear To Send (JP1 “B”)
RTS
Request To Send (JP1 “B”)
Table 1-1
Front Panel Components
(continued)
Component Description
Содержание InfiniteStorage 3000