44
Chapter 3: Operating the Storage System
Output of the command raid5 -d device 5 might be
12/17/94 09:59;51 A3: (A07) Cru Powered Down [0x47]
12/17/94 09:59;51 A3: (608) Cru Ready [0x0]
12/17/94 09:59;51 A3: (603) Cru Rebuild Started [0x0]
12/17/94 09:59;51 A3: (604) Cru Rebuild Complete [0x0]
12/17/94 09:59;51 A3: (602) Cru Enabled [0x0]
These entries show that a field-replaceable unit (disk module, fan unit,
battery backup unit, SP) has failed, been replaced, been rebuilt, and been
enabled.
At the tail of each log entry is an error code in brackets (for example,
[0x47]
)
that gives diagnostic information when it is available. See “getlog” in
Appendix B for explanations of these codes.
To clear the event log, use
raid5
-d device
clearlog
Note:
You must be root to use the clearlog parameter.
Shutting Down the CHALLENGE RAID Storage System
Follow these steps to shut down the CHALLENGE RAID storage system:
1.
If you are using storage system caching, make sure that it is disabled;
use raid5 getcache to check status. If necessary, disable it with raid5
setcache disable, as explained in Chapter 7.
2.
Turn off the power switch on the back of the CHALLENGE RAID
storage system, as shown in Figure 3-3.
Note:
You do not need to disable the power for the SP(s).