110
Appendix B: The raid5 Command Line Interface
VSCC State: Present
SPA State: Present
SPB State: Present
BBU State: Present
Table B-4 interprets items in this output. Values for all entries of the output
are Present or Not Present, except as noted.
getdisk
For information on all bound disks in the system, use
raid5 -d
device
getdisk
For information on a particular disk, use
raid5 -d
device
getdisk [
diskposition
]
In this command, diskposition has the format bd, where b is the bus on which
the disk is located (a through e) and d is the device number (0 through 3).
Figure B-1 diagrams disk module locations.
Table B-4
Output of raid5 getcrus
Output
Meaning
FANA
,
FANB
Fan banks A and B.
VSCA
Power supply (voltage semi-regulated converter).
VSCB
Optional second power supply.
SPA
Storage control processor.
SPB
Optional second storage-control processor.
BBU
Battery backup unit, which has three states: Faulted (removed),
Charging, and Present (fully charged or charging).
If the battery backup unit takes longer than an hour to charge, it
shuts itself off and transitions to the “Faulted” state.
Содержание CHALLENGE RAID