![Silicon Graphics Altix XE320 Скачать руководство пользователя страница 51](http://html.mh-extra.com/html/silicon-graphics/altix-xe320/altix-xe320_user-manual_1271640051.webp)
Check the Node Board Setup
007-5466-001
23
Install Expansion PCIe Cards
You can install two expansion PCIe cards in the system. Refer to Chapter 4 for details on installing
PCIe expansion cards.
Check all Cable Connections and Airflow
Make sure all power and data cables are properly connected and not blocking the chassis airflow.
Refer to Chapter 4 for details on cable connections.
Check the Drive Bay Setup
Next, you should check to make sure the SATA/SAS drives and SATA/SAS backplane have been
properly installed and all connections have been made.
Check the SATA/SAS Drives
Depending upon your system configuration, your system may have one or more drives installed.
For detailed information about how to install SATA/SAS drives, refer to Chapter 5, “Advanced
Chassis Setup.”
Check the Airflow
Airflow is provided by six sets of 4-cm fans (each set of fans consists of two fans that are mounted
back to back). The system component layout was carefully designed to direct sufficient airflow to
cool the components that generate the most heat. Note that all power and data cables have been
routed in such a way that they do not block the airflow generated by the fans. An air shroud is also
installed to focus the airflow to areas where the most heat is generated.
Supply Power to the System
If necessary, install the system in a rack (refer to “Install the System into a Rack” on page 12), and
connect the power cord from the power supply module into a power strip or power distribution
unit (PDU). The PDU offers protection from electrical noise and power surges. SGI also
recommends that you use an uninterruptible power supply (UPS) source.
Содержание Altix XE320
Страница 1: ...SGI Altix XE320 System User s Guide 007 5466 001 ...
Страница 3: ...007 5466 001 iii Record of Revision Version Description 001 February 2008 Initial publication ...
Страница 4: ......
Страница 16: ......
Страница 20: ......
Страница 28: ......
Страница 45: ...Install the System into a Rack 007 5466 001 17 Figure 2 6 Install the Server in a Rack ...
Страница 52: ......
Страница 56: ......
Страница 84: ...56 007 5466 001 4 Advanced Node Board Setup Figure 4 9 Replace DIMMs ...
Страница 110: ......
Страница 119: ...Power Supply 007 5466 001 91 Figure 5 6 Power Supply Replacement Power supply Lever 2 1 2 1 ...
Страница 120: ......
Страница 160: ......
Страница 178: ...150 007 5466 001 B IPMI 2 0 Management Utility Functions Listed on the Home Page Figure B 1 BMC Remote Console ...
Страница 182: ...154 007 5466 001 B IPMI 2 0 Management Utility CD ROM Image Figure B 3 CD ROM Image ...
Страница 184: ...156 007 5466 001 B IPMI 2 0 Management Utility Drive Redirection Figure B 4 Drive Redirection ...
Страница 186: ...158 007 5466 001 B IPMI 2 0 Management Utility Virtual Media Options Figure B 5 Virtual Media Options ...
Страница 198: ...170 007 5466 001 B IPMI 2 0 Management Utility Figure B 10 User Console Settings ...
Страница 216: ...188 007 5466 001 B IPMI 2 0 Management Utility Figure B 19 Device Information ...
Страница 230: ......
Страница 238: ......
Страница 242: ......
Страница 248: ......