Install Memory
007-5467-001
3-49
Memory DIMM Rules
Use the following rules when installing memory DIMMs:
•
A minimum of two DIMMs must always be present.
•
DIMMs within pairs must be identical in:
•
Size (1, 2, or 4 GB)
•
Speed (667 or 800 Mtransfer/sec)
•
Organization (x4 or x8 bit)
•
DIMMs do not need to be identical between DIMM pairs. DIMM pair 1A/2A can be
different from DIMM pair 3A/4A in size, speed and organization.
Note:
The memory controller hub automatically adjusts to the lowest speed DIMM of the DIMM
pair.
•
When configuring the memory for maximum performance, it is critical that the memory
DIMM capacity is balanced across both memory branches (refer to
Figure 3-9
).
The MCH memory controller has two memory branches: Branch 0 and Branch 1. DIMMs 1A, 2A,
1B, and 2B are on branch 0 and DIMMs 3A, 4A, 3B, and 4B are on branch 1. If the total capacity
of the memory DIMMs on each branch are not balanced, memory performance is degraded.
•
Install DIMMs with the same capacity in the following order:
•
2 DIMMs - Install DIMM pair 1
•
4 DIMMs - Install DIMM pair 1 and 2
•
8 DIMMs - Install DIMM pair 1, 2, 3, and 4
•
12 DIMMs - Install DIMM pairs 1, 2, 3, 4, 5, and 6
•
16 DIMMs - All DIMM slots filled
Содержание Altix XE250
Страница 1: ...SGI Altix XE250 System User s Guide 007 5467 001 ...
Страница 3: ...007 5467 001 iii Record of Revision Version Description 001 February 2008 Original printing ...
Страница 4: ......
Страница 16: ...xvi 007 5467 001 Contents ...
Страница 20: ...xx 007 5467 001 Figures ...
Страница 28: ......
Страница 50: ...2 22 007 5467 001 2 Server Installation Figure 2 3 Install the Server in a Rack 2 1 ...
Страница 55: ...Node Board Installation 007 5467 001 3 27 Figure 3 1 Remove the Top Cover 2 1 2 1 1 2 ...
Страница 57: ...Node Board Installation 007 5467 001 3 29 Figure 3 2 Node Board Replacement 2 1 ...
Страница 80: ...3 52 007 5467 001 3 Advanced Node Board Setup Figure 3 11 Replace DIMMs ...
Страница 116: ...3 88 007 5467 001 3 Advanced Node Board Setup ...
Страница 123: ...Fans 007 5467 001 4 95 Figure 4 4 Fan Replacement 2 1 Fan 1 Fan 2 Fan 3 ...
Страница 132: ...4 104 007 5467 001 4 Advanced Chassis Setup Figure 4 12 Power Supply Replacement Power supply Lever 2 1 ...
Страница 176: ...5 148 007 5467 001 5 BIOS Settings ...
Страница 186: ...A 158 007 4960 004 A BIOS Power on Self Test ...
Страница 191: ...Functions Listed on the Home Page 007 5467 001 B 163 Functions Listed on the Home Page Figure B 2 BMC Remote Console ...
Страница 195: ...Virtual Media 007 5467 001 B 167 CD ROM Image Figure B 4 CD ROM Image ...
Страница 197: ...Virtual Media 007 5467 001 B 169 Drive Redirection Figure B 5 Drive Redirection ...
Страница 199: ...Virtual Media 007 5467 001 B 171 Virtual Media Options Figure B 6 Virtual Media Options ...
Страница 211: ...KVM Settings 007 5467 001 B 183 Figure B 11 User Console Settings ...
Страница 229: ...Maintenance 007 5467 001 B 201 Figure B 20 Device Information ...
Страница 236: ...B 208 007 5467 001 B IPMI 2 0 Management Utility ...
Страница 244: ......
Страница 252: ......
Страница 258: ...I 230 007 5467 001 Index ...