![Silicon Graphics Altix XE1300 Скачать руководство пользователя страница 28](http://html.mh-extra.com/html/silicon-graphics/altix-xe1300/altix-xe1300_quick-reference-manual_1271616028.webp)
20
007-4979-004
1: SGI Altix XE1300 Cluster Quick-reference
InfiniBand Switch Connect and IP Address
The subsection “Web or Telnet Access to the InfiniBand Switch” on page 20 lists the factory IP
address settings for your InfiniBand switch or switch “stack” used with the cluster. For clusters
with greater than 288 network ports, consult SGI Professional Services for specific IP address
configuration information.
Web or Telnet Access to the InfiniBand Switch
Your InfiniBand switch(s) setup is configured in the factory before shipment and should be
accessible via telnet or a web browser.
Note:
There might be only one managed InfiniBand switch when multiple InfiniBand switches
are used in blocking configurations.
To access the managed InfiniBand switch via telnet:
telnet 10.0.21.1
Login as the administrator:
login
admin
passwd:
123456
Web access would be:
http://10.0.21.1
javaws
(java Webstart) is required for use of the InfiniBand fabric GUI.
SLES 9 service pack 3 location of
javaws
is:
/usr/java/j2re1.4.2_12/javaws/javaws
SLES 10 location of
javaws
is:
/usr/bin/javaws or
/usr/java/jre1.5.0_11/javaws