A: InfiniBand Fabric Details
11. Use the the
ibnetdiscover
command to verify the fabric, as follows:
r01lead:/ # ibnetdiscover -l
Switch
: 0x08006900000000dc ports 24 devid 0xb924 vendid 0x2c9 "MT47396 Infiniscale-III Mellanox Technologies"
Switch
: 0x08006900000000a4 ports 24 devid 0xb924 vendid 0x2c9 "MT47396 Infiniscale-III Mellanox Technologies"
Ca
: 0x0030487aa7940000 ports 1 devid 0x6274 vendid 0x2c9 " HCA-1"
Ca
: 0x0030487aa78c0000 ports 1 devid 0x6274 vendid 0x2c9 " HCA-1"
Ca
: 0x0008f10403988198 ports 2 devid 0x6278 vendid 0x8f1 "service0-ib0 HCA-1"
Ca
: 0x0030487aa7840000 ports 1 devid 0x6274 vendid 0x2c9 " HCA-1"
Ca
: 0x0030487aa79c0000 ports 1 devid 0x6274 vendid 0x2c9 " HCA-1"
Ca
: 0x0030487aa7900000 ports 1 devid 0x6274 vendid 0x2c9 " HCA-1"
Ca
: 0x0030487aa7980000 ports 1 devid 0x6274 vendid 0x2c9 " HCA-1"
Ca
: 0x0008f104039881a8 ports 2 devid 0x6278 vendid 0x8f1 " HCA-1"
Note:
Get usage information on the
ibnetdiscover
command, as follows:
r01lead:/ # ibnetdiscover --help
Usage: ibnetdiscover [-d(ebug)] -e(rr_show) -v(erbose) -s(how) -l(ist) -g(rouping) -H(ca_list)
-S(witch_list) -V(ersion) -C ca_name -P ca_port -t(imeout) timeout_ms --switch-map switch-map]
--switch-map
specify a switch-map file
12. Exit the rack leader controller (leader node) and return to the admin node, you
should be good to go now.
54
007–5450–001
Содержание Altix ICE 8000 Series
Страница 1: ...Scali ManageTM On SGI Altix ICE System Quick Reference Guide 007 5450 001 ...
Страница 3: ...Record of Revision Version Description 001 April 2008 Original publication 007 5450 001 iii ...
Страница 4: ......
Страница 8: ......
Страница 10: ......
Страница 11: ...Examples Example A 1 opensm ib0 conf and opensm ib conf Configuration Files 45 007 5450 001 xi ...
Страница 12: ......
Страница 13: ...Procedures Procedure A 1 Configuring and Initializing the InfiniBand Fabric Manually 51 007 5450 001 xiii ...
Страница 14: ......