General Information
81
General Information
Read the following subsections for additional safety information and required tools.
Safety Information
Before beginning the replacement procedures, observe these precautions.
Warning:
This equipment uses electrical power internally that is hazardous if the
equipment is improperly disassembled. Board removal and replacement should be
performed only by SGI-certified personnel.
Caution:
Do not attempt to move CrayLink Interconnect cables. These cables are made
of sensitive copper strands and insulation material that can be damaged if they are
excessively bent, stretched, or stepped on.
This equipment is extremely sensitive and susceptible to damage by electrostatic
discharge (ESD) which is caused by the buildup of electrical static potential on clothing
and other materials. Use proper ESD preventive measures and observe these
precautions:
•
Wear a properly grounded wrist strap when connecting and disconnecting
peripherals.
•
Be sure that you and all the electrical equipment you handle are at ground potential
to avoid damage from ESD. Do not rely on the power source ground; the ground is
lost when the system is disconnected from the power source.
•
Keep boards in their antistatic bags until you are properly grounded to the chassis
ground with a ground strap.
•
Do not use an ohmmeter or a digital voltmeter on a board.
Содержание 2400
Страница 1: ...SGI 2400 and 2800 Server Owner s Guide Document Number 007 4192 001 ...
Страница 8: ......
Страница 12: ......
Страница 14: ......
Страница 20: ......
Страница 22: ...2 Chapter 1 Introducing the SGI 2400 and 2800 Server Systems Figure 1 1 SGI 2400 Rackmount Server System ...
Страница 23: ...System Features 3 Figure 1 2 SGI 2400 Multirack System Configuration Example ...
Страница 34: ......
Страница 48: ...28 Chapter 2 Chassis Tour Figure 2 7 Node Board Positioning in the Chassis Node 1 Node 4 Node 3 Node 2 ...
Страница 71: ...Rackmount Configurations 51 Figure 4 4 16P SGI 2400 Server Node boards Router boards Midplane R1 R2 R3 R4 ...
Страница 78: ......
Страница 81: ...Connecting Your Terminal 61 Figure 5 1 Connecting a Terminal Terminal Console port ...
Страница 87: ...Loading the CD ROM 67 Figure 5 4 Installing a CD ROM Into an SGI 2400 or 2800 Chassis Retainers Retainers ...
Страница 91: ...Initially Powering On the System 71 Figure 5 7 Turning On the PDU PDU off PDU on PDU power switch ...
Страница 98: ......
Страница 107: ...General Procedures 87 Figure 6 5 Turning Off the PDU PDU off PDU on PDU power switch ...
Страница 113: ...Specific Procedures 93 Figure 6 10 Removing the Drive Handle in open position Handle in closed position ...
Страница 117: ...Specific Procedures 97 Figure 6 12 Removing the System Controller and CD ROM ...
Страница 142: ......