22
Chapter 2: Chassis Tour
System Controller
There are two types of System Controllers used in the servers—a single module System
Controller (MSC) and a multimodule System Controller (MMSC) and display. The MSC
does not have the same functional abilities as the MMSC. For detailed information on
operating the System Controller, see Chapter 7, “Using the System Controller.”
MSC and Display
The MSC and display (Figure 2-4) provide environmental and status monitoring for an
individual system module.
MMSC and Display
The MMSC and display (see Figure 2-5) are the single-point administration interface for
the rackmount configuration. The individual module controllers are tied to the
multimodule controller through an eight-pin serial connection from the module to the
multimodule controller board in the rack.
The MMSC and display are two separate units as shown in Figure 2-1 and Figure 2-2.
There should only be one multimodule display per configuration to act as the
single-point administration for the rack configuration. In addition, in a multirack
configuration, the rack with the MMSC and display should always be placed in the
leftmost position (see Figure 1-2 and Figure 1-3 in Chapter 1).
Caution:
The front panel display provides a convenient method to power on, shutdown,
reset, and to issue a nonmaskable interrupt (NMI) to the
entire
rack configuration. Use
extreme care when issuing these commands from the display. Make sure that all affected
users are notified before a system-wide command is executed.
Содержание 2400
Страница 1: ...SGI 2400 and 2800 Server Owner s Guide Document Number 007 4192 001 ...
Страница 8: ......
Страница 12: ......
Страница 14: ......
Страница 20: ......
Страница 22: ...2 Chapter 1 Introducing the SGI 2400 and 2800 Server Systems Figure 1 1 SGI 2400 Rackmount Server System ...
Страница 23: ...System Features 3 Figure 1 2 SGI 2400 Multirack System Configuration Example ...
Страница 34: ......
Страница 48: ...28 Chapter 2 Chassis Tour Figure 2 7 Node Board Positioning in the Chassis Node 1 Node 4 Node 3 Node 2 ...
Страница 71: ...Rackmount Configurations 51 Figure 4 4 16P SGI 2400 Server Node boards Router boards Midplane R1 R2 R3 R4 ...
Страница 78: ......
Страница 81: ...Connecting Your Terminal 61 Figure 5 1 Connecting a Terminal Terminal Console port ...
Страница 87: ...Loading the CD ROM 67 Figure 5 4 Installing a CD ROM Into an SGI 2400 or 2800 Chassis Retainers Retainers ...
Страница 91: ...Initially Powering On the System 71 Figure 5 7 Turning On the PDU PDU off PDU on PDU power switch ...
Страница 98: ......
Страница 107: ...General Procedures 87 Figure 6 5 Turning Off the PDU PDU off PDU on PDU power switch ...
Страница 113: ...Specific Procedures 93 Figure 6 10 Removing the Drive Handle in open position Handle in closed position ...
Страница 117: ...Specific Procedures 97 Figure 6 12 Removing the System Controller and CD ROM ...
Страница 142: ......