You can test this connection by using the TELNET utility from the Windows Command Prompt (MS-DOS
prompt), Mac OS X Terminal Utility, or UNIX/Linux command line as follows:
telnet
ipaddress portnumber
where i
paddress
is the IP address of the SX-550 and
portnumber
is the SX-550 TCP port number. For
example:
telnet 192.168.5.53 9100
In this example, if you have a serial printer or other device capable of displaying ASCII characters
connected to the SX-550 Serial Port 1, then every character you type should be printed on that serial
device (buffered serial devices may need you to type a control character such as a formfeed (CONTROL-
L) before the characters are printed).
RFC 2217 Support
RFC 2217 allows you to connect from a host computer over the wireless or Ethernet network to a serial
device attached to the serial port of the SX-550, even if the baud rate of that device does not match the
baud rate of the host computer’s software. For example, if the host computer software was set to 57.6Kbs
and the SX-550 serial port was set to 19.2Kbps, the RFC 2217 support would take care of the mismatch.
RFC 2217 also allows you to access your device’s modem control signals over the network. It is
especially useful for migrating applications that use modem controls from a direct serial connection to a
serial device server network connection (RFC 2217 modem signal support is supported in SX-550
firmware versions 2.04 and higher).
You can utilize RFC 2217 from the Silex Serial Port Emulator software (see above), or by connecting to
TCP port 9200 from your application program.
The RFC 2217 features supported by the SX-550 include:
•
SET and QUERY baud rate
•
SET and QUERY character size
•
SET and QUERY parity
•
SET and QUERY stop bits
•
SET (and query) outbound flow control setting (separate input & output flow control not
supported)
•
SET outbound break state **
•
QUERY inbound break state **
•
SET and QUERY DTR state
•
SET and QUERY RTS state (SET only if not HW flow control)
•
DCD, DSR & RI line monitoring **
** Requires 2.04 or later firmware
*** Only the break bit is tested to generate a notification, not the various transmit/receive status registers
(TX empty, etc).
ECable Mode
Normally, it is up the computer to initiate a connection to the SX-550. For some applications, it is
desirable for the SX-550 to initiate the connection to the computer. The SX-550 supports this capability
through its ECable feature.
Part Number 40183-101
Silex SX-550 Developer's Guide
Page 36
Содержание SX-550
Страница 1: ...SX 550 Embedded Intelligent Module Developer s Reference Guide Revision L...
Страница 3: ......
Страница 10: ...Part Number 40183 101 Silex SX 550 Developer s Guide Page 2...
Страница 26: ...Part Number 40183 101 Silex SX 550 Developer s Guide Page 18...
Страница 40: ...Part Number 40183 101 Silex SX 550 Developer s Guide Page 32...
Страница 111: ...Part Number 40183 101 Silex SX 550 Developer s Guide Page 103...
Страница 112: ...Appendix C Engineering Drawings Antenna Part Number 40183 101 Silex SX 550 Developer s Guide Page 104...
Страница 118: ...Part Number 40183 101 Silex SX 550 Developer s Guide Page 110...
Страница 122: ...silex technology america Inc www silexamerica com Part Number 40183 101 Silex SX 550 Developer s Guide Page 114...