Remote Panic (Optional beeping horn feature must be installed)
Note 1: The optional horn beep feature must be installed and the vehicle must have a factory installed
Remote Keyless Entry System for the Remote Panic option to operate.
At any time the model 6905P can be placed into personal panic mode. To activate this feature simply
press the “Lock” button on your keyless entry transmitter 4 times consecutively. The vehicle horn will
begin beeping. To turn off the panic alarm once it is activated, press the “Unlock” button on your keyless
entry transmitter.
Note 2: Once activated, the personal panic alarm feature will sound for 60 seconds and then turn off by
itself unless the “Unlock” button is press to turn it off.
Chirp Delete
If your system was delivered to you with the horn beep feature installed, it can be turned off. Ask your
dealer for additional information.
Optional Features (Continued)
System Override / Valet Mode Operation
In the event that your Silencer key or your factory keyless entry transmitter becomes lost or inoperative,
you can override your Silencer system by using your ignition key and your removable valet switch. In
addition, if you allow another person to drive your car such as a mechanic, parking attendant or a friend,
the override system can also be used as a valet system. Valet Mode will disable the security system. To
test these features, repeat the following procedures:
Note: The black removable override/valet switch installs in the rear of the receptacle.
To Enter Override/Valet Mode (System is Disarmed)
1. Turn on the ignition key.
2. Depress the override / valet switch. You will feel the switch click to it’s “In” position.
3. The LED stays on continuously.
4. Turn off the ignition key and you are “In” valet mode.
5. The vehicle can be started at all times with the ignition key.
To Exit Override / Valet Mode
1. Turn on the ignition key.
2. Depress the override/valet switch. You will feel the switch click to its “Out” position.
3. Turn off the ignition key and you are “Out” of the valet mode.
4. The system will now resume normal operations.
Primary Feature Operations
3