LAB939R, Issue 2, July 2014
Page 4
1.0
General description (all models)
1.1
Overview
1.1.1 The
Silavent HRX2
appliance is a key part of a whole house ventilation system specifically
designed to improve indoor air quality in dwellings. The system is designed to provide
measured amounts of filtered, fresh air to living areas while constantly removing polluted,
stale air from bathing, cooking and washing areas at the same gentle rate.
Any available heat
in the outgoing stale air is recovered by a built-in heat exchanger and used to pre-warm the
fresh supply air.
1.1.2 A manual boost switch is provided to increase the ventilation rate, e.g. when cooking or
showering thereby maintaining a comfortable indoor environment.
1.1.3 The boost facility can also be triggered from a lighting circuit or by a range of sensors,
including humidity control and movement detection (supplied separately – see section 1.1.8)
1.1.4 The G3/EU3 filters in the appliance ensure that the fresh supply air is clean as it enters the
home. Additionally, the stale extract air is filtered to protect the heat exchanger from
unwanted contamination. These filters have to be cleaned regularly, depending on the levels
of pollution. The filters should be replaced when they start to show visible signs of wear.
1.1.5 This product is listed in SAP Appendix Q, therefore, part of the installation process requires
that an installation checklist is completed and submitted to the Building Control Body (BCB).
Blank checklists are available at
www.sap-appendixq.org.uk
1.1.6 Pack includes:
•
Silavent HRX2 appliance
•
Two duct connection plates and a bag of 18
fixing screws.
•
Wiring centre
•
Ventilation control switch - either one gang boost control (models HRX2-S, HRX2-FP) or two
gang combined boost and summer bypass control (models HRX2-B, HRX2-BFP)
•
Installation and operating instructions manual and ‘householder-instruction cover’ with fixings
1.1.7 Ancillary items required:
•
Domus Ø150mm rigid duct system (Domus 220mm x 90mm rectangular can be used in
restricted spaces), or Domus radial duct system (see 2.8)
•
Optional Domus HRX2-CK1 ‘soft’ duct connection kit (see 2.8.3)
•
Domus Thermal duct insulation (see 2.8.4)
•
Domus 297 condensate drainage kit (see 2.7)
1.1.8 Ancillary options (see page 20)
•
Silavent adjustable overrun timer, code ANC108A
•
Silavent humidity control (with adjustable overrun timer), code ANC802A
•
Silavent humidity control (with adjustable overrun timer and remote sensor), code ANC846A
•
Silavent humidity control (with adjustable overrun timer and manual override with neon
indicator), code ANC808A
•
Silavent PIR movement control (with adjustable overrun timer), code ANC813A
•
Silavent 6-Switched live backfeed protected junction box, code ELE150R
Содержание Green Line HRX2 Series
Страница 5: ...LAB939R Issue 2 July 2014 Page 5 ...
Страница 16: ...LAB939R Issue 2 July 2014 Page 16 HRX2 S wiring diagram ...
Страница 17: ...LAB939R Issue 2 July 2014 Page 17 HRX2 B wiring diagram ...
Страница 18: ...LAB939R Issue 2 July 2014 Page 18 HRX2 FP wiring diagram ...
Страница 19: ...LAB939R Issue 2 July 2014 Page 19 HRX2 BFP wiring diagram ...
Страница 23: ...LAB939R Issue 2 July 2014 Page 23 Notes ...