Communication via CAN bus (CANopen and CANopen Safety)
IKM360M
Date: 21.01.2021
Art. No. 90444
Mod. status 222/20
Page 54 of 58
Sub-index
01h
Description
Safety calibration value for longitudinal slope (Safety Slope long16 preset
value).
Access
ro when NMT state is operational
rw when NMT state is pre-operational
PDO mapping
no
Data type
INTEGER 16
Default
0h
EEPROM
yes
Data content
0h … FFFFh
5.8.2.32
6210h: Safety Slope long16 (Safety longitudinal slope value)
The Safety Slope long16 (Safety longitudinal slope value) can be read byte by byte via object
6210h.
Sub-index
00h
Description
indicates the largest supported sub-index
Access
const
PDO mapping
no
Data type
UNSIGNED 8
Default
2h
EEPROM
no
Sub-index
01h
Description
Safety slope long16 1
st
byte
Access
ro
PDO mapping
no
Data type
INTEGER 8
Default
0h
EEPROM
no
Sub-index
02h
Description
Safety slope long16 2
nd
byte
Access
ro
PDO mapping
no
Data type
INTEGER 8
Default
0h
EEPROM