Communication via CAN bus (CANopen and CANopen Safety)
IKM360M
Date: 21.01.2021
Art. No. 90444
Mod. status 222/20
Page 40 of 58
Sub-index
03h
Description
set only application parameters to factory settings (6000h … 9FFFh, CiA
410)
Access
rw
PDO mapping
no
Data type
UNSIGNED 32
Default
1h
EEPROM
no
Data content
Write:
Byte 0
Byte 1
Byte 2
Byte 3
6Ch ("l")
6Fh ("o")
61h ("a")
64h ("d")
Read:
Bit 31 … 1
0: reserved
Bit 0
1: Device permits loading of default parameters.
Sub-index
04h
Description
set only manufacturer-specific parameters to factory settings (2000h …
5FFFh)
Access
rw
PDO mapping
no
Data type
UNSIGNED 32
Default
1h
EEPROM
no
Data content
Write:
Byte 0
Byte 1
Byte 2
Byte 3
6Ch ("l")
6Fh ("o")
61h ("a")
64h ("d")
Read:
Bit 31 … 1
0: reserved
Bit 0