AS510/1
Output signals English
AS510/1 · Date
23.05.2017 · Art.
No.
82049 · Mod.
status
304/16
18
6 Output signals
The follower electronics used together with AS510/1 should be suitable for
the pulse width (or counter frequency) chosen.
Translation module AS510/1 converts the magnetic length information
supplied by a magnetic sensor into incremental output signals. These sig-
nals are issued speed-proportionally. It must be taken into account that
pulses with a width of the set pulse spacing can occur at standstill (result-
ing from the internal interpolation method).The pulse distance can be
changed be adjusting the DIP-switch (see
). This change will influ-
ence the maximum travel speed directly (see chapter
).
Signal sequence
With resolution 0.1 mm the index signal has a length of 0.5 increments
only.
The zero reference signal appears every 5 mm, irrespective of the resolution.
Fig. 3: Output signals A and B with reference signal (1 increment)
5 mm
5 mm
5 mm
B
A
0
Resolution / pulse distance
Please check whether the pre-programmed values (chapter
) are suit-
able for your follower electronics (e. g. counter card). If parameters need
to be changed, e. g. to adapt the pulse width, please proceed as described
in chapter
7 Commissioning
When mounted an connected correctly, translation module AS510/1 can
be switched on.
The unit then carries out an auto-initialization. 'POWER'-LED at the front
of the unit comes on (see
When the magnetic sensor moves, LEDs A and B at the front of AS510/1
come on.
NOTICE
NOTICE