VT...40
Technical data
Technical changes reserved
- 31 -
8.2
VT...40 with analogue output, version AI
Type
VTH40
VTM40
Characteristics measurement device
Measuring range
(See type plate for scaling)
0...150 l/min*
0...250 l/min*
0...400 l/min*
Accuracy
-
Turbine
-
Transducer
±
7 % of reading (0.4…3 m
3
/h)
±
5 % of reading (3…25 m
3
/h)
±1.25 % of reading
Repeatability
±
0.5 %
Signal output from
> 0.28 m³/h (> 4.7 l/min)
Sensor
Hall effect sensor
Characteristics output signal
Output signal
4…20 mA
Signal current
~ 26 mA
Max. load
250
Ω
against GND
Residual ripple
0.2 mA (peak to peak) over the entire range
Electrical characteristics
Supply voltage
18…30 VDC
Max. current consumption
30 mA
Type
3-wire, galvanically not separated, common GND of power supply and out-
put signal
Electrical connection
4-pin plug connector, M12x1
Degree of protection
(EN 60529)
IP 54
Process variables
Medium temperature, max.
80 °C
Medium temperature, min.
0 °C, non-freezing
Ambient temperature
0…75 °C
0…85 °C
Nominal diameter
DN 40
Nominal pressure
PN 10
PN 50
Particle size in the medium
< 0.63 mm
Integrated screen filter
Flat filter, mesh size 0.63 mm
Process connection
G 2 male thread, supplementary screwed connection recommended
* Not suitable for continuous operation.