12
ADDRESS=
Used to display the Bluetooth address of the local adaptor.
?
Inquire the Bluetooth address of the local adaptor.
AT
Check the connection status between control terminal and the
RS-232 adapter. Response: "OK" when the connection is ok.
Response: "ERROR" when the connection is not correct.
AT
Test the RS-232 status when first connect the adapter with the
controller.
AUTO=
Used to enable/disable auto-connection feature. It is available
only when the adaptor is in the master role.
The command is available when DIP=N. The system will not
re-start after change.
Y
The Master role adapter will connect the latest paired
Bluetooth device automatically.
(Default)
N
The user will connect the Bluetooth device manually.
?
Inquire the current setting.
BAUD=
Used to specify the baud rate of COM port.
The command will have 200 ms delay.
1200
1200 bps
2400 2400
bps
4800 4800
bps
9600 9600
bps
(Default)
19200 19200
bps
38400
38400 bps
57600 57600
bps
115200 115200 bps
230400 230400 bps
460800 460800 bps
921600 921600 bps
R
Restore the default settings. (Baud rate =19200 bps)
?
Inquire the current baud rate.