(d) Necessary Capacity of MaxiCode
The total remaining capacity of area1 to 2 shown in Table 6-13 is necessary for MaxiCode print.
For an example, when number of bar code data byte=33;
Area 1 = 33+1 = 34 bytes
Area 2 = 7684 bytes
Total = 7718 bytes
(Assume that the remaining capacity is even number of bytes.)
Table 6-13 GS 'p' 3 MaxiCode Print Necessary Capacity
Area Capacity
(Bytes)
Area 1
N bytes
1
*
Area 2
7684 bytes
*1:N: Number of bar code data
When remaining capacity of the RAM is an odd number, one more byte is necessary.
When number of bar code data byte is an odd number, one more byte is necessary.