background image

Sigrand IP video cameras, Release 1.0.101

The result of the conguring is the set of rules connecting an incoming event (motion

detector, input signal, system startup) to an action (output signal, alarm sound playing,

sending of a picture).

2.3.7.1 Add

The Add button creates a new rule, opening the rules editor:

52

Chapter 2. User Guide

Содержание SG-1C-111

Страница 1: ...Sigrand IP video cameras Release 1 0 101 November 02 2015 ...

Страница 2: ......

Страница 3: ...f SG 1C 1 1 7 1 3 1 1 Back panel socket SG 1C 1 1 8 1 3 2 Back panel of SG 3C 1312 10 1 3 3 Back panel of SG 3C 1612 11 2 User Guide 13 2 1 Initial setup 13 2 2 Resetting 14 2 3 User interface 14 2 3 1 Status bar 14 2 3 2 Watch video 15 2 3 2 1 Stream 16 2 3 2 2 Video in a new window 16 2 3 2 3 URL 16 2 3 2 4 Image parameters 16 2 3 2 5 Autofocus 16 2 3 2 6 Zoom 16 2 3 2 7 Focus 17 2 3 3 Device 17...

Страница 4: ... 3 4 4 Motion detect 44 2 3 5 Audio 46 2 3 5 1 Enable 47 2 3 5 2 Audio codec 47 2 3 5 3 Audio bitrate 47 2 3 5 4 Input and Output volume 47 2 3 6 Recording 47 2 3 6 1 Enable recorder 49 2 3 6 2 Container format 49 2 3 6 3 File size limit 49 2 3 6 4 File duration limit 49 2 3 6 5 Circular recording 49 2 3 6 6 MicroSD card 50 2 3 7 Events 51 2 3 7 1 Add 52 2 3 7 2 Edit 55 2 3 7 3 Remove 55 ii ...

Страница 5: ...ncy of using network bandwidth They are especially advantageous when used in wide open spaces such as an entrance to a building or airport or in applications where precise identi cation is required for instance of the face of a person or the number in a vehicle registration plate Figure 1 1 SG 1C 1 1 These cameras have replaceable image sensor allowing operation in a High Dynamic 1 ...

Страница 6: ... glaring light Implementation of the cameras is based on one of the most state of the art digital video processors from Texas Instruments DaVinci TMS320DM368 http processors wiki ti com index php Category DaVinci http www ti com product tms320dm368 The cameras can be connected in a chain and powered over Ethernet PoE with the whole group being powered through the same cable for this purpose a 2 po...

Страница 7: ...G 1C 121 1 3 CMOS Aptina AR0331 3 1 Mpix SG 1C 131 1 2 5 CMOS Aptina MT9P006 5 Mpix SG 3C 1312 1 2 5 CMOS Aptina MT9P006 5 Mpix Day and Night Mechanical IR lter Minimum intensity of illumination SG 1C 111 0 20 lux F 1 2 color 0 03 lux F 1 2 black white SG 1C 121 0 1 lux F 1 2 black white Dynamic range SG 1C 111 up to 120 dB SG 1C 121 up to 100 dB SG 1C 131 up to 76 dB SG 3C 1312 up to 76 dB 1 1 Te...

Страница 8: ...80 30 fps Image adjustment options Brightness contrast sharpness automatic white balance automatic exposure day night mode horizontal and vertical mir roring on screen display for arbitrary text date time histogram 1 1 3 Audio Audio stream Bi directional Audio codecs G 711 8 KHz 64 Kbit s AAC LC 8 KHz adjustable bitrate Input and Output Microphone input and line output 1 1 4 Network Con trol Web i...

Страница 9: ...D ash Camera box Cast of aluminum alloy Lens mounting type CS External dimensions LxWxH mm 120 x 65 x 50 Weight g 150 Operating conditions 50 50 C with a weather proof housing IPhouse 15E and 35 50 C without weather proof housings Network interface 2 x Ethernet 10 100 Power supply Local 12V or PoE class 2 with a feature of through line powering of several cameras Power consumption W 4 5 1 2 Power ...

Страница 10: ...E mode A or B is used the other one PoE mode B port must be left unconnected When cameras are connected into a chain only mode B is to be used i e power must be supplied through spare pairs In this case one of the camera ports is to be connected either to the power supply source or to the previous camera and the other is to be connected to the next camera in the chain Thus in each camera spare pai...

Страница 11: ...Sigrand IP video cameras Release 1 0 101 1 3 Back Panel 1 3 1 Back panel of SG 1C 1 1 Left to right downward 1 3 Back Panel 7 ...

Страница 12: ...et SG 1C 1 1 Socket at the camera rear panel rear view Socket pinout 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Pin description 01 02 03 04 RS 232 DTE port for weather proof housing management Connector pin RS 232 signal 01 TxD 02 RxD 03 GND 04 12 V Note Onto the camera connector pin 04 power supply voltage 12 V is fed which is used at the controller side as a power supply source for optical couple...

Страница 13: ...ting the UART to the corresponding mode in the Device General pad through the pop down menu serial port type 05 06 12 RS 232 DCE port for console Connector pin RS 232 signal DB 9F pin COM port 05 RxD 2 06 GND 5 12 TxD 3 The default parameters of the port are 115200 baud 8N1 The device le in the camera is dev ttyS1 07 13 14 alarm inputs and outputs Connector pin Function 07 ALARM_IN2 13 ALARM_OUT 1...

Страница 14: ...G 3C 1312 Left to right downward PoE In PoE Ethernet socket PoE Out PoE Ethernet socket Both sockets are interconnected through a PoE Ethernet switch Reset hidden software reset button MicroSD socket for Micro SD cards upside down 10 Chapter 1 Cameras description ...

Страница 15: ...rm input and output are halvanically isolated by optical coupler Alarm input is activated by supplying voltage in range of 2 4 volts or by current 1 16 mA with external resistor Optical coupler input is sequence of LED and 220 Ohm resistor Alarm output is open collector type The output is short to ground when asserted Maximum voltage is 60 V and maximum current is 400 mA 1 3 Back Panel 11 ...

Страница 16: ...Sigrand IP video cameras Release 1 0 101 12 Chapter 1 Cameras description ...

Страница 17: ... patch cord in case you have a separate power supply source for your camera or to an Ethernet switch with a PoE option Assign temporarely the IP address 192 168 2 0 24 subnet mask 255 255 255 0 for the corresponding PC interface and through your Web browser to go to the camera address 192 168 2 200 The cameras Web interface will automatically redirect Web browser from the port of unprotected HTTP ...

Страница 18: ... In case the connection with camera is lost and would not restore you can reset it to the factory defaults with the exception for the Ethernet MAC address through the following routine switch o the power of the camera switch on the power of the camera after 10 seconds after the camera is powered press the hidden Reset button at the camera rear panel for 1 2 seconds with a toothpick or a straighten...

Страница 19: ...s of the operation de nes the state Image Sensor Shows the type of image sensor Firmware version Shows the version of installed rmware 2 3 2 Watch video The item at the very top of the menu Watch video opens by default and shows the camera video in the default format H 264 through RTSP RTP unless other streaming formats are set Note The browser shows the reduced size of the image in its initial si...

Страница 20: ... 2 Video in a new window The button Video in a new window opens the video in a separate new window so as not to lose the video when passing to other items in the menu 2 3 2 3 URL The URL string contains the URL through which the current video stream is received The URL can be given to other client programs in order to make the video stream from the camera available to them 2 3 2 4 Image parameters...

Страница 21: ... in the appropriate direction Works only on cameras with motorized lens 2 3 3 Device 2 3 3 1 General The Device General tab shows the general parameters and settings of the device Hardware platform It shows the version of the Texas Instruments Inc SoC chip The possible values are dm368 dmva2 Firmware version The version of rmware is shown 2 3 User interface 17 ...

Страница 22: ... from the port of unprotected HTTP 80 to the port of protected HTTPS 443 The default value is on Serial port type The pop down menu for setting the type of the serial port used in managing of a weather proof housing or a PTZ drive The possible values are RS 232 RS 485 The default value is RS 232 2 3 3 2 Network The Device Network tab is used to adjust the networking settings of the device General ...

Страница 23: ... The default value is empty Local domain name The input eld is value of domain directive of etc resolv conf le Example sigrand local The default value is empty Hostname The input eld for the name of the device hostname The default value is sigTIcam This eld is the same as the one in Device General tab 2 3 User interface 19 ...

Страница 24: ...CP ECN switches the corresponding ag http en wikipedia org wiki Explicit_Congestion_Noti cation of the network stack of the device OS kernel The default value is on IP spoo ng protection The ag IP spoo ng protection switches the corresponding ag http en wikipedia org wiki IP_spoo ng of the network stack of the device OS kernel in order to prevent the corresponding network attack The default value ...

Страница 25: ...ation les The default value is 00 00 11 22 33 44 Get IP address automatically DHCP The ag permitting to get the IP address automatically through the DHCP Depends on availability of a DHCP server in the network and on the servers settings If the con guration of the DHCP server does not provide that a xed IP address should be assigned to this Ethernet MAC address in most cases a vacant pseudo random...

Страница 26: ...twork address The default value is 255 255 255 0 Default gateway In the eld Default gateway the IP address of the router is de ned The default value is 192 168 2 1 The eld can be left blank or assigned the value 0 0 0 0 In local networks there is no need for a gateway however it can be useful for the following purposes to have Internet access for the device which allows its connection with NTP ser...

Страница 27: ...ime shift of the local time against the Universal Time Coordinated UTC The default value is Asia Novosibirsk Mutually exclusive ags Keep current date and time No time manipulations are performed Synchronize with your computer time Manual Time is set by entering it manually 2 3 User interface 23 ...

Страница 28: ... is gateway timeserver ru telecom mipt ru ntp psn ru ttm chant ru Note The rst server gateway is a reference to the variable containing Default gate way In case there is an NTP server established at the gateway the device will get time synchronization from the server 2 3 3 4 Users The Device Users tab is used for adjusting users settings It gives the possibility to change the Web admin password ad...

Страница 29: ...5 Con guration The Device Con guration tab is used to save the current con guration of the device to a le at the le system of the PC which run browser to restore the device con guration from the le and to reset the con guration 2 3 User interface 25 ...

Страница 30: ...create it with a command in a user shell of your computer ssh keygen t rsa Generating public private rsa key pair Enter file in which to save the key home tst ssh id_rsa Created directory home tst ssh Enter passphrase empty for no passphrase Enter same passphrase again Your identification has been saved in home tst ssh id_rsa Your public key has been saved in home tst ssh id_rsa pub The key finger...

Страница 31: ...3UkH9uAeUssw2czQxSryHdQZaRgdCliFPdq07NYB1pQxWDcX2ES3C wv6g2lsHQyHmvrxcxFmxYQ U9LtW7fk 5Ad2piSJkvKQgbxU4uvFnHlBT0y0Kl Zhd3wd5STEWMF2q9FORpROMZz9pb ALnCQgSXjEBJRcrq8fwu74t E 5P1n8If 2 1Vwk1v Gen71O6xvcWICmPPs QO twGOA6cVmFHg4 Ag91yoC2 jCU4kQhjm lVuaUSRCL2UWhltJJjRCXkdf jJgfN1WhJjsMoSizH1u6fC1ju1B12C2gqn73m qVPTc9Jn tst sigrand and select it with a triple click of the left mouse button Insert the sel...

Страница 32: ...ograms for Windows PuTTY SecureCRT ShellGuard Axessh ZOC SSHWindows ProSSHD or XShell and the routine of creating keys will be di erent 2 3 3 7 File browser The Device File browser tab can be used to view the list of les of the mounted le systems of the device view and edit les save a device le to the computer where the Web browser is started start or remove a le 28 Chapter 2 User Guide ...

Страница 33: ...Sigrand IP video cameras Release 1 0 101 View edit le etc hosts 2 3 User interface 29 ...

Страница 34: ...Sigrand IP video cameras Release 1 0 101 2 3 3 8 Firmware The Device Firmware tab is used to update the rmware of the device 30 Chapter 2 User Guide ...

Страница 35: ...button checks availability of a new rmware version at the manufacturer site if the camera has access to the Internet If the latest version at the manufacturer site is newer than current one a message New version available is shown 2 3 User interface 31 ...

Страница 36: ...choosing a rmware update le by the Browse button The le should be downloaded beforehand from the manufacturer site The rmware update les are published at the site of the device manufacturer http sigrand ru dl camera ti rmware and have the following form sigticam platform version tar After choosing the rmware update le click the button Update and Reboot 32 Chapter 2 User Guide ...

Страница 37: ...nd IP video cameras Release 1 0 101 It takes up to 90 seconds to perform reboot with rmware update 2 3 4 Video 2 3 4 1 General The Video General tab adjusts the general video parameters 2 3 User interface 33 ...

Страница 38: ...parameters of the second and third video streams The default value depends on the type of the image sensor 1920 x 1080 for AR0331 and MT9P006 1280 x 720 for MT9M034 Custom stream The input elds Width and Height for parameters of the second stream if it is enabled by Sensor mode The default values is 640 x 360 34 Chapter 2 User Guide ...

Страница 39: ...rent frequency for the illuminating lamps which create the e ect of the image ickering The possible values are No No icker compensation is made 50 Hz Flicker compensation is made for the lamps fed by 50 Hz current 60 Hz Flicker compensation is made for the lamps fed by 60 Hz current Horizontal Flip Vertical Flip The ags of horizontal and vertical mirroring are used to switch on rotatory re ection ...

Страница 40: ...ken with various exposures are superposed to produce a single fully featured high quality frame of natural contrast and color grade This feature allows surveillance in a complicated environment for instance when the site of surveillance gets alternately in the sun and in the shade or when the camera is spotlighted with directional glaring light The HDR mode is presented only for image sensors MT9M...

Страница 41: ...of displaying time in the video The possible values are 12 24 The default value is 24 Date and Time position The pop down menu Date and Time position de nes where to display the date and time The possible values are Bottom Right Bottom Left The default value is Bottom Right 2 3 4 2 Stream N The Video Stream N tabs where N is the stream number 0 1 show the settings for the video streams the size of...

Страница 42: ...Sigrand IP video cameras Release 1 0 101 38 Chapter 2 User Guide ...

Страница 43: ...sed to set the codec type for the current stream The possible values are No The stream is shut o MJPEG Motion JPEG This codec is available for streaming through HTTP and RTSP MPEG4 MPEG 4 The codec so far is only available for streaming through RTSP H 264 2 3 User interface 39 ...

Страница 44: ...e range of values is 2 000 000 12 000 000 Values below 512 000 are also possible but not recommended JPEG quality The input eld and graphic slider bar JPEG quality are used to adjust the image quality compression degree parameter for JPEG frames The range of values is 3 98 The default value is 75 The higher the value the better the image quality and the lower the compression degree and the larger ...

Страница 45: ...e default value is O QP initial min max The input eld for entering the initial minimum and maximum values of the codec Quantization Parameter QP The range of values is 1 31 for MPEG 4 codec and 1 51 for H 264 codec Preset The pop down menu Preset The possible values are AUTO CUSTOM SVC The default value is AUTO Packet size In the eld Packet size the packet size is de ned in terms of percentage Tim...

Страница 46: ...ine Top right Top left Text string In the input eld Text string you can enter a users text line The length of the line must not exceed 23 printed 7 bit ASCII characters from the fol lowing set A Za z _ 0123456789 In order to prevent falling down of the camera audio video server characters outside this set will be substituted as follows to space Double quote to single quote Others to Extra symbols ...

Страница 47: ...ransfer of media stream Multicast streaming greatly reduces the tra c in case of multiple clients HTTP tunneling The HTTP Tunneling checkbox turns on HTTP based tunneling mode of packet streaming It is useful for bypassing restrictions of the Internet provider HTTP tunneling port The HTTP tunneling port input eld speci es a port for the HTTP tunnel 2 3 User interface 43 ...

Страница 48: ... fully supported by such browsers as Mozilla Firefox Iceweasel Google Chrome and to no extent by Mi crosoft Internet Explorer and Opera Enable The Enable checkbox enables streaming by HTTP HTTP port The HTTP port input eld speci es a port for the HTTP streaming server of the camera Default setting 8080 2 3 4 4 Motion detect The Motion detect tab manages the motion detector settings 44 Chapter 2 Us...

Страница 49: ...treams The window is partitioned into 12 equal rectangulars de ning sensitive areas of the motion detector By a left click of the mouse corresponding area is turned on or o Disabled areas do not take part in motion detection The changes are activated by pressing the Save button Select all The Select All button turns on all motion detector areas 2 3 User interface 45 ...

Страница 50: ... all button turns o all motion detector areas Sensitivity level The Sensitivity level pulldown menu changes the motion detector sensitivity Low Medium High 2 3 5 Audio The Audio tab is used for adjusting the audio subsystem of the device 46 Chapter 2 User Guide ...

Страница 51: ...itrate The input eld Audio bitrate is used to select the stream bitrate For G 711 codec the only possible value is 64000 For AAC codec the range of values is 24000 128000 2 3 5 4 Input and Output volume The input elds and graphic slider bars Input volume and Output volume are used to set the values of the corresponding regulators of the hardware mixer The range of values is 0 100 The default value...

Страница 52: ...me is found whereupon the le is closed Then a new le opens and begins with the last keyframe Thus subsequent les have a one frame overlap and always begin with a keyframe Files have names derived from their start time in the local timezone YYYY MM DD_hh mm ss msc ext where YYYY year MM month number DD day of month hh hours mm munutes ss seconds 48 Chapter 2 User Guide ...

Страница 53: ... 256 Since the SD Card is formatted in FAT32 the le size limit is 4 GiB It is recommended to specify the size less than 4096 MiB with a good margin because upon reaching the limit a few frames more and a format de ned tail are written If the le reaches the 4096 MiB limit it is forcedly closed by the lesystem and the recording process stops and does not restart automatically 2 3 6 4 File duration l...

Страница 54: ...2 5 minutes Unmount The Unmount button unmounts the card lesystem stopping the recording processes and allows you to remove the card from the camera safely The other techinque of the safe card removal Pressing the Reset button on the back camera panel for 0 5 1 0 seconds If the card is inserted the Reset button changes its function and makes unmounting of the card After 30 60 seconds taken for saf...

Страница 55: ...e Unmount button inserted mounted The card is inserted into the slot and mounted Partitions The Partitions section dispays the list of partitions of the inserted card Example MiB type 1 60906 W95 FAT32 where partiniton number MiB partition size in MiB type partition type Browse les The Browse les button opens the le browser at the root of the card lesystem 2 3 7 Events The Events tab allows to de ...

Страница 56: ... guring is the set of rules connecting an incoming event motion detector input signal system startup to an action output signal alarm sound playing sending of a picture 2 3 7 1 Add The Add button creates a new rule opening the rules editor 52 Chapter 2 User Guide ...

Страница 57: ... Disabling the rules allows you to save them without applying Name The Name input eld de nes the name of the rule It exists only for user s convenience and performs no function It can be left empty Event The Event pulldown list speci es one of the available incoming events 2 3 User interface 53 ...

Страница 58: ...tions Output Signal A logic 1 pulse about 3 3 V is applied to Pin 13 of the rear panel connector The duration of the pulse is speci ed in milliseconds by the Output Signal Dura tion input eld The default state of the output signal is logic 0 Play Alarm An alarm audio signal is applied to the analog line output of the camera Send Picture A single JPEG frame is sent to the URL de ned by the Destinat...

Страница 59: ...ds For example 2013 10 25_19 25 33 153 jpeg Usually a few frames are sent by a motion detection event 2 3 7 2 Edit The Edit button changes an existing rule chosen by a left click of the mouse by opening the rules editor 2 3 7 3 Remove The Remove button deletes an existing rule chosen by a left click of the mouse 2 3 User interface 55 ...

Отзывы: