SignitePro C30000CLF Скачать руководство пользователя страница 29

29

WARRANTY 

The manufacturer warrants that your new product 

is free from manufacturing and material defects 

for a period of one year from date of purchase,      

subject to the following conditions and limitations:

1. This product must be installed and operated at       

    all times in accordance with the instructions

    furnished with the product. Any alteration,

    willful abuse, accident, or misuse of the product   

    shall nullify this warranty. 

2. This warranty is non-transferable, and is made   

    to the original owner, provided that the

    purchase was made through an authorized        

    supplier of the manufacturer. 

3. This warranty is limited to the repair or

    replacement of part(s) found to be

    defective in material or workmanship, provided    

    that such part(s) have been subjected to normal

    conditions of use and service, after said defect   

    is confirmed by the manufacturer’s inspection. 

4. The manufacturer may, at its discretion, fully   

    discharge all obligations with respect to this

    warranty by refunding the wholesale price of the

    defective part(s). 

5.  Any installation, labor, construction,                   

    transportation, or other related costs/expenses   

    arising from defective part(s), repair, 

    replacement or otherwise of same, will not be   

    covered by this

    warranty, nor shall the manufacturer assume       

    responsibility for same. Further, the 

    manufacturer will not be responsible for any          

    incidental, indirect, or consequential

    damages, except as provided by law. 

6. All other warranties - expressed or implied with

    respect to the product, its components and

    accessories, or any obligations/liabilities on the      

    part of the manufacturer are hereby expressly   

    excluded. 

7. The manufacturer neither assumes, nor 

    authorizes any third party to assume, on its      

    behalf, any other liabilities with respect to the  

    sale of this product. 

8. The warranties as outlined within this document 

    do not apply to non-manufacturer accessories  

    used in conjunction with the installation of this   

    product. 

This warranty is void if:

 

a) The product has been operated in atmospheres  

    contaminated by chlorine, fluorine or other           

    damaging chemicals. 

b) The product is subjected to prolonged periods 

    of dampness or condensation. 

c) Any alteration, willful abuse, accident, or misuse  

    of the product. 

IF WARRANTY SERVICE IS NEEDED ...

 

1) Contact customer service at 519-442-4848.  Make sure you have your warranty, your sales receipt, 

and the model/serial number of your product. 

2) 

DO NOT ATTEMPT TO DO ANY SERVICE WORK YOURSELF. 

WARRANTY REGISTRATION

IMPORTANT

: We urge you to file your warranty registration within fourteen (14) days 

of date of purchase. Register your warranty on the internet at www.SignitePro.com or 

through your local distributor.

Application Questions?  Missing Parts? Before returning appliance to retailer, please 

contact  customer  service  department  between  9am  EST  -  3pm  EST  @  (519)  -  442-4848                   

email us at: [email protected]

Содержание C30000CLF

Страница 1: ...n from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air For Combustion and Ventilation section on page 7 of this manual INSTALLER...

Страница 2: ...U hr 15 000 15 000 15 000 15 000 Fuel Type Natural Gas Natural Gas Propane Propane Natural Gas Natural Gas Propane Propane Ignition Electronic Push Button Electronic Push Button Electronic Push Button...

Страница 3: ...ter will remain hot for a time after shutoff Allow surfaces to cool before touching WARNING Make sure any panel safety screen or guard removed for servicing an appliance is replaced prior to operating...

Страница 4: ...in a bedroom These units are not approved for bathroom use 3 This heater needs fresh air ventilation to run properly This heater has an Oxygen Depletion Sensing ODS safety shutoff system The ODS shut...

Страница 5: ...ner on and off to maintain a desired room temperature For further information see page 20 State of Massachusetts The installation must be made by a licensed plumber or gas fitter in the Commonwealth o...

Страница 6: ...Water vapor is a by product of gas combustion An unvented room heater produces approximately one 1 ounce 30 mL of water for every 1 000 BTU 3 Kw of gas input per hour An unvented room heater is inten...

Страница 7: ...LY TIGHT CONSTRUCTION The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation However in buildings of unusually tight construction you must provide addi...

Страница 8: ...as heater ___________ BTU hr Gas heater logs ___________ BTU hr Other gas appliances ___________ BTU hr Total ___________ BTU hr Do not include direct vent gas appliances Direct vent draws combustion...

Страница 9: ...se items directly to the outdoors or spaces open to the outdoors These spaces include attics and crawl spaces Follow the National Fuel Gas Code NFPA 54 ANS Z223 1 Air for Combustion and Ventilation fo...

Страница 10: ...ng wall than required CAUTION This heater creates warm air currents These currents move heat to wall surfaces next to the heater Installing the heater next to vinyl or cloth wall coverings or operatin...

Страница 11: ...NOT dispose of batteries in fire Improper disposal may cause batteries to leak or explode PREINSTALLED FAN OPTIONAL WARNING This appliance is equipped with a three prong grounding plug for your prote...

Страница 12: ...ts wire connected to the receptacle mounting screw ACCESSING FAN 1 Turn off gas supply to appliance 2 Remove appliance from mounted position if applicable 3 Remove screws connecting front heater cover...

Страница 13: ...ION FAN WIRING ASSEMBLY DIAGRAM ELECTRICAL SCHEMATIC RED RED BLUE BLUE RED RED BLUE ON OFF AUTO SWITCH THERMAL SWITCH TO POWER CORD YELLOW GROUND YELLOW GROUND AUTO MANUAL OFF MOTOR AUTO MANUAL OFF TH...

Страница 14: ...er will be placed for leg installation to prevent scratching of the table and or the heater Set back of heater on table with the bottom of heater extending outside the table edge Fasten Support Legs t...

Страница 15: ...mounting Drill 5 16 in holes at least 1 in deep WARNING ELECTRICAL PLUMBING OR GAS LINES MAYBE IN WALL Before cutting drilling or hammering verify their location If needed contact your electrician plu...

Страница 16: ...ppliance using 2 wall hanging spacer screws 4 8 x 25 Check that the spacers are secure before mounting appliance Spacer Wall Hanging Spacer Screw Fig 13 Locate Mounting Slots on upper left right of ap...

Страница 17: ...line pressure is higher the unit will not work and heater regulator damage could occur CAUTION Never connect the heater directly to a LP supply This heater requires an external regulator not supplied...

Страница 18: ...5 kPa Leak Testing Heater Gas Internal Connections 1 Open equipment shutoff valve see Fig 15 2 Make sure control knob of the heater is in the OFF position 3 Open gas supply tank valve LP systems 4 Che...

Страница 19: ...y to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If y...

Страница 20: ...ilot is visible centered below the burner behind the front grill see Fig 18 Do not attempt to light the pilot by hand 7 Keep control knob depressed for 30 seconds after pilot lights Release control kn...

Страница 21: ...cool which shuts the heater off If pilot flame pattern is incorrect turn heater off see To Turn Off Gas to Appliance on page 21 see Troubleshooting pages 25 through 27 Ignitor Control Knob OFF P I L O...

Страница 22: ...orrect Abnormal Flame Pattern with tall flames with Control Knob Set to High Flame Infrared Flame NOTE Before servicing you will need to remove the front panel of the heater There are 4 tapping screws...

Страница 23: ...TION While the appliance is running press the switch to the MANUAL position see Fig 28 The fan will run continuously until turned to AUTO or OFF A DETAIL A SCALE 1 2 MANUAL Fig 28 MANUAL Switch Positi...

Страница 24: ...servicing CAUTION You must keep the control areas burner and circulating air passageways of the heater clean Inspect these areas of the heater before each use Have the heater inspected yearly by a qu...

Страница 25: ...lectrode is positioned wrong 2 Ignitor electrode is broken 3 Ignitor electrode is not connected to ignitor cable 4 Ignitor cable is pinched or wet 5 Damaged ignitor cable 6 Bad ignitor or ignition mod...

Страница 26: ...burner s 1 Manifold pressure is too low 2 Burner orifice is clogged 1 Contact your gas supplier 2 Clean burner orifice see Care and Maintenance on page 24 or contact customer service Burner backfiring...

Страница 27: ...ontrol valve is defective 1 Locate and correct all leaks see Checking Gas Connections on page 18 2 Contact customer service Moisture condensation noticed on windows 1 Not enough combustion ventilation...

Страница 28: ...L 1 1 10 Bracket of Furnace 1 1 1 1 11 Furnace Supporter 1 1 1 1 12 Ignitor Module 1 1 1 1 13 Ignitor Bracket 1 1 1 1 14 Front Grille 1 1 1 1 15 Support Leg 2 2 2 2 16 Spacer 2 2 2 2 17 Rear Side Oute...

Страница 29: ...sponsible for any incidental indirect or consequential damages except as provided by law 6 All other warranties expressed or implied with respect to the product its components and accessories or any o...